Test and Calibration Repair Instruction Electrical/
1262-4107
Rev
1
Sony Mobile Communications AB – Company Internal
3(8)
1
Go/No Go Testing
This Go/No Go testing has to be carried out in tow ways, with an:
•
Antenna Coupler.
•
Cable in shield box
For more information on Antenna Coupler and Cable in shield box testing, refer to
1220-1336: Generic Repair Manual – electrical, section ‘Setup Go/NoGo Test’!
For part no’s on the equipment below, refer to the ‘Tools Catalogue/Matrix’!
1.1 Antenna Coupler
The following equipment has to be used:
•
Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box
- Rohde & Schwartz RF Coupler
- Grid Positioning Holder
•
RF Test Cable Flexible 1M
•
RF Adapter for RF Shield Box
•
USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1900/2100
Put the grid positioning holder with its reference point in
position
G13
and place the phone as shown in the adjacent
picture.
A
F
E
D
B C
G H I
N
M
L
J K
O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
A
F
E
D
B C
G H I
N
M
L
J K
O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
Содержание MT25i
Страница 72: ...1262 4098 Rev 1 Sony Mobile Communications AB Company Internal Test Instructions mechanical MT25i Xperia neo L ...
Страница 135: ...1262 4102 Rev 1 Sony Mobile Communications AB Company Internal Repair Movies mechanical Xperia neo L MT25i ...
Страница 139: ...1262 4103 Rev 2 Sony Mobile Communications AB Company Internal Part List mechanical MT25i Xperia neo L ...
Страница 147: ...1262 4107 Rev 1 Sony Mobile Communications AB Company Internal Go No Go Test electrical MT25i ...
Страница 155: ...1262 4125 Rev 2 Sony Ericsson Mobile Communications AB Company Internal Customization build swap Xperia neo L MT25i ...