1-9 (E)
MPE-200
2. KY-660 board
<Switch >
Ref No.
Address
Name
Function
Factory setting
S102
(A-2)
_
S102-1: Bank switching of NOR flash memory
All OFF
ON: Backup
OFF: Main
S102-2: Sets the starting mode.
ON: Automatically starts when the AC
power turns on.
OFF: Does not start automatically.
S102-3: Sets the starting path.
ON: Forcibly starts in the maintenance mode.
OFF: Starts with the path set on the firmware.
S102-4 to 6: Not used
S102-7, 8: Sets the RS-232C function
*
1
*
1: Setting the RS-232C function
S102-7
S102-8
Front side RS-232C
*
*
*
*
*
2
Rear side RS-232C
OFF
OFF
Not used
Console/System control mode
ON
OFF
Console mode
System control mode
OFF
ON
Console/System control mode
Not used
ON
ON
Not used
Not used
*