MEX-BT4100E/BT4100P/BT4100U/BT4150U
4
NOTE THE MAIN BOARD OR SYSTEM CONTROLLER
(IC501) REPLACING
When the MAIN board or system controller (IC501) is replaced,
the destination setting is necessary.
1. Destination Setting
Set destination according to the procedure below.
1-1. Setting the Destination Code
1. In the state of source off (the clock is displayed), enter the test
mode by pressing the buttons in order of the [SHUF 4]
t
[MIC/ZAP 5]
t
[PAUSE 6] (press only the [PAUSE 6] button
for two seconds).
2. In the state in which the system controller version is displayed
on the liquid crystal display (refer to following
fi
gure), enter
the destination setting mode by pressing the buttons in order
of the [SEEK+
> M
]
t
[
m
.
SEEK–]
t
[PUSH EN-
TER/MENU/
APP].
(Displayed characters/values in the following
fi
gure are ex-
ample)
System controller version
SHUF
3. Input the alphanumeric character of 12 digits of “F XXXXXX”
displayed on the liquid crystal display, and execute the destina-
tion setting.
Note:
Refer to following “1-3. Entering the Destination Code” for opera-
tion method.
4. The resetting operation is executed by pressing the [
OFF
SOURCE] button for 1 second after the setting ends, and the
unit returns to the normal condition.
1-2. Display in Destination Setting Mode
(Displayed characters/values in the following
fi
gure are example)
Destination code
12 digit
OP5 OP4 OP3 OP2 OP1 OP0
SHUF
1-3. Entering the Destination Code
• Method of operation by main unit
1. Rotate the control dial, and select the alphanumeric character
of “0 to F”.
2. The digit advances by pressing the [PUSH ENTER/MENU/
APP] or [SEEK+
> M
] button.
The digit returns by pressing the [ MODE] or [
m
.
SEEK–] button.
3. The setting is completed by pressing the [PUSH ENTER/
MENU/
APP] button, and the initialization operation is done.
• Method of operation by remote commander
1. Press the [ ] or [ ] button, and select the alphanumeric char-
acter of “0 to F”.
2. The digit advances by pressing the [
] button.
The digit returns by pressing the [
] button.
3. The setting is completed by pressing the [ENTER] button, and
the initialization operation is done.
1-4. Destination Code
Model
Destination OP5 OP4 OP3 OP2 OP1 OP0
MEX-BT4100E
Russian
C
C
1
5
8
7
MEX-BT4100P
US, Canadian
5
E
1
5
6
2
MEX-BT4100U AEP, UK
4
C
1
5
7
1
MEX-BT4150U E, Mexican
4
C
1
D
9
0
MEX-BT4150U Saudi Arabia
4
C
1
D
9
4
2. Con
fi
rmation After Destination Setting
Execute the following operation after completing the destination
setting, and con
fi
rm a correct destination was set.
Destination setting checking method:
1. In the state of source off (the clock is displayed on the liquid
crystal display), enter the test mode by pressing the buttons in
order of the [SHUF 4]
t
[MIC/ZAP 5]
t
[PAUSE 6] (press
only the [PAUSE 6] button for two seconds).
2. In the state in which the system controller version is displayed
on the liquid crystal display (refer to following
fi
gure), enter
the destination setting value display mode by pressing the [
SCRL DSPL] button three times.
(Displayed characters/values in the following
fi
gure are ex-
ample)
System controller version
SHUF
3. Con
fi
rm the alphanumeric character of 12 digits in liquid crys-
tal display is an value correctly input.
(Displayed characters/values in the following
fi
gure are ex-
ample)
Destination code
12 digit
OP5 OP4 OP3 OP2 OP1 OP0
SHUF
4. The resetting operation is executed by pressing the [
OFF
SOURCE] button for 1 second after the con
fi
rming ends, and
the unit returns to the normal condition.
Ver. 1.1
Содержание MEX-BT4100P
Страница 75: ...MEMO MEX BT4100E BT4100P BT4100U BT4150U 17 ...