4-7. Test Mode Displays
The DISPLAY key is used to switch display modes. The display modes are switched in the following order each time the DISPLAY key is
pressed.
Display
H
X
z
REC
SYNC (other models/TOC EDIT)
L. SYNC (other models/A.SPACE)
OVER
B/1 (REP portion)
A-/REP
TRACK/(LP)4/calender frame
DISC/LP2
SLEEP/SHUF
MONO
PROGRAM
Contents
MODE display
Off
Servo ON
Servo OFF
Tracking servo OFF
Tracking servo ON
Recording mode OFF
Recording mode OFF
CLV low speed mode
CLV normal mode
ABCD adjustment completed
Tracking offset cancel ON
Tracking offset cancel OFF
Tracking auto gain OK
Focus auto gain OK
Pit
Groove
High reflection
Low reflection
CLV-S
CLV-A
CLV LOCK
CLV UNLOCK
EF BAL change
4-8. Meaning of Other Displays
Order
Description
Example of display
1
MODE display
CPLAY1 (
2
Error rate display
C=
AD=
3
Address display
h
s
4
Auto gain display
AG=
/
[
]
5
Detrack display
ADR=
# 0000
6
IVR display
[
] [
] [
]
7
Displays C1 error and JITTER
J
C
8
Displays AD error and JITTER
J
AD=
When CPLAY or CREC starts, the display is forced to switch to 2 as initial mode.
Supplementary explanation of each display
1. MODE display
“TEMP ADJUS” (C03), “CPLAY1MODE” (C34), etc. are displayed.
2. Error rate display
Error rates are displayed as follows.
C=
AD=
C= means the C1 error and AD= means ADER.
3. Address display
Addresses are displayed as follows.
h=
s=
(pit block of recordable disc and disc for playback only)
h=
a=
(groove of recordable disc)
h= means the header address, s= means the SUBQ address and a= means the ADIP address.
* When the address cannot be read, “-” is displayed.
Displays other than the above ones are not used for service.
4-9. Information
Displays the version of software.
[Operation procedure]
1. Press the YES button while “INFORMATION” is displayed.
2. The version of the software will be displayed.
3. End this mode with the MENU/NO button.
4-10. Countermeasure when MEMORY NG Appears
If there is an abnormality in non-volatile memory data, “E001” / “MEMORY NG” appears so that the MO deck is not operated. If this
happens, immediately enter the test mode and do the following.
[Operation procedure]
1. Enter the test mode. (Refer to Section 4-2.)
2. The display for selecting the test mode normally appears. However, if there is an abnormality in non-volatile memory data, the following
characters appears: “INIT EEP?”
3. Press the
x
button and
A
button at the same time.
4. Rotate the
l
AMS
L
knob to select “MBU-5J”.
5. Press the
l
AMS
L
knob. If the non-volatile memory data succeeds in being rewriting, the mode returns to the norma test mode
and the display for selecting modes appears.