5-26
21. CCD Black Defect Compensation Check
Mode
STILL
Subject
Clear chart
(25 cm from the front of lens)
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Specified Value
00
Note 1:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2:
Any subject other than the clear chart should be in the
screen.
Note 3:
Perform “CCD Black Defect Compensation” before this
checking.
Checking method:
1) Turn the power of the unit OFF and then ON.
2) Wait until the camera picture appear on the LCD screen.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: E, address: 52, after noting down the data, set
data: 50, and press the PAUSE button of the adjusting remote
commander.
5) Select page: F, address: AF, set data: A5, and press the PAUSE
button of adjusting remote commander.
6) Select page: 6, address: 2C, and set data: 01.
7) Select page: 6, address: 90, and set data: 00.
8) Select page: 6, address: 91, and set data: 04.
9) Select page: 6, address: 92, and set data: 00.
10) Select page: 6, address: 93, and set data: 00.
11) Select page: 6, address: 01, set data: 79, and press the PAUSE
button of adjusting remote commander.
12) Select page: 6, address: 30, and set data: 07.
13) Select page: 6, address: 01, set data: 89, and press the PAUSE
button of adjusting remote commander.
14) Select page: 6, address: 02, and check that the data is “01”.
15) Select page: 6, address: 55, and check that the data is “00”.
(If the data other than “00”, black defect compensation has
errors)
Processing after Completing Adjustments:
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of adjusting remote commander.
2) Select page: 6, address: 30, and set data: 00.
3) Select page: 6, address: 91, and set data: 00.
4) Select page: 6, address: 2C, and set data: 00.
5) Select page: F, address: AF, set data: B3, and press the PAUSE
button of adjusting remote commander.
6) Select page: E, address: 52, set data noted down at step 4) and
press the PAUSE button of the adjusting remote commander.
7) Select page: 0, address: 01, and set data: 00.
22. CCD White Defect Compensation Check
Mode
STILL
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Specified Value
07 or less
Note 1:
Perform “CCD Black Defect Compensation” before this
checking.
Checking method:
1) Turn the power of the unit OFF and then ON.
2) Wait until the camera picture appear on the LCD screen.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: F, address: B3, set data: 80, and press the PAUSE
button of adjusting remote commander.
5) Turn the power of the unit OFF.
6) Wait for 2 second.
7) Turn the power of the unit ON.
8) Select page: 6, address: 55, and check that the white defection
data is satisfies the specified value.
9) Select page: F, address: B3, set data: A0, and press the PAUSE
button of adjusting remote commander.
10) Select page: 6, address: 01, set data: 87, and press the PAUSE
button of adjusting remote commander.
11) Select page: 6, address: 02, and check that the data is “01”.
12) Select page: 6, address: 55, and check that the data is “00”.
(If the data other than “00”, white defect compensation has
errors)
Processing after Completing Adjustments:
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of adjusting remote commander.
2) Select page: F, address: B3, set data: 20, and press the PAUSE
button of adjusting remote commander.
3) Select page: 0, address: 01, and set data: 00.
Содержание Mavica MVC-FD83
Страница 8: ...1 1 SECTION 1 GENERAL This section is extracted from instruction manual MVC FD83 FD88 ...
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 ...
Страница 18: ...1 11 ...
Страница 19: ...1 12 ...
Страница 20: ...1 13 ...
Страница 21: ...1 14 ...
Страница 22: ...1 15 1 15 E ...
Страница 27: ...MVC FD83 FD88 3 1 3 2 3 3 SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM to ...
Страница 33: ...MVC FD83 FD88 4 1 4 2 4 3 4 1 FRAME SCHEMATIC DIAGRAM SECTION 4 PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS ...