5-25
19. Strobe Light Level and White Balance Check
Check the light level regulation and the white balance when the
strobe light flashed.
Mode
STILL
Subject
A plate which reflection rate is 18%
(1.0 m from the front of lens)
Measurement Point
Displayed data of page: 1
Measuring Instrument
Adjusting remote commander
Specified Value
Y level data: 68 to A0 (Note 3)
R-Y level data: FA to FF or 00 to
06 (Note 4)
B-Y level data: FA to FF or 00 to
06 (Note 4)
Note 1:
Perform this adjustment in the dark room or use a dark
box.
Note 2:
Any light other than the strobe light should not light up
the plate.
Note 3:
The right two digits of the page: 1displayed data of the
adjusting remote commander
1:00:XX
→
Y level data
Note 4:
The right four digits of the page: 1displayed data of the
adjusting remote commander
1:XX:XX
→
B-Y level data
→
R-Y level data
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: E, address: 52, after noting down the data, set
data: 1B, and press the PAUSE button of the adjusting remote
commander.
3) Select page: 6, address: 10, and set data: 58.
4) Select page: 6, address: 90, and set data: 00.
5) Select page: 6, address: 91 and set data: 00.
6) Select page: 6, address: 92, and set data: 00.
7) Select page: 6, address: 93, and set data: 60.
8) Select page: 6, address: 2C, and set data: 01.
9) Select page: 6, address: 01, set data: 79, and press the PAUSE
button of the adjusting remote commander.
10) Select page: 6, address: 01, set data: 67, and press the PAUSE
button of the adjusting remote commander.
11) Check the flashing of strobe light.
12) Select page: 0, address: 03, and set data: 01.
13) Select page: 1, and check the Y level (Note 3) data satisfies the
specified value.
14) Select page: 0, address: 03, and set data: 02.
15) Select page: 1, and check the R-Y, B-Y level data (Note 4)
satisfies the specified value.
Processing after Completing Adjustments:
1) Select page: 0, address: 03, and set data: 00.
2) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 6, address: 2C, and set data: 00.
4) Select page: 6, address: 93, and set data: 00.
5) Select page: 6, address: 10, and set data: 00.
6) Select page: E, address: 52, set data noted down at step 2) and
press the PAUSE button of the adjusting remote commander.
7) Select page: 0, address: 01, and set data: 00.
20. CCD Black Defect Compensation
Mode
STILL
Subject
Clear chart
(25 cm from the front of lens)
Measurement Point
Displayed data of page: 1,
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
B
Adjustment Address
88 to AF
Specified Value
0A or less
Note 1:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: E, addresses: 88 to AF, and input data: FF to each
address.
Note:
Press the PAUSE button of the adjusting remote com-
mander each time to set data.
3) Select page: E, address: 52, after noting down the data, set
data: 50, and press the PAUSE button of the adjusting remote
commander.
4) Select page: F, address: AF, set data: B3, and press the PAUSE
button of adjusting remote commander.
5) Select page: 6, address: 2C, and set data: 01.
6) Select page: 6, address: 90, and set data: 00.
7) Select page: 6, address: 91, and set data: 04.
8) Select page: 6, address: 92, and set data: 00.
9) Select page: 6, address: 93, and set data: 00.
10) Select page: 6, address: 01, set data: 79, and press the PAUSE
button of adjusting remote commander.
11) Select page: 6, address: 30, and set data: 07.
12) Wait for 2 second.
13) Select page: 6, address: 01, set data: 8D, and press the PAUSE
button of adjusting remote commander.
(The CCD defect compensation is performed and the compen-
sation data is stored in page: B, address: 88 to AF)
14) Select page: 6, address: 02, and check that the data is “01”.
15) Select page: 6, address: 55, and check that the black defection
data is satisfies the specified value.
Processing after Completing Adjustments:
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of adjusting remote commander.
2) Select page: 6, address: 91, and set data: 00.
3) Select page: 6, address: 2C, and set data: 00.
4) Select page: 6, address: 30, and set data: 00.
5) Select page: E, address: 52, set data noted down at step 3) and
press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Содержание Mavica MVC-FD83
Страница 8: ...1 1 SECTION 1 GENERAL This section is extracted from instruction manual MVC FD83 FD88 ...
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 ...
Страница 18: ...1 11 ...
Страница 19: ...1 12 ...
Страница 20: ...1 13 ...
Страница 21: ...1 14 ...
Страница 22: ...1 15 1 15 E ...
Страница 27: ...MVC FD83 FD88 3 1 3 2 3 3 SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM to ...
Страница 33: ...MVC FD83 FD88 4 1 4 2 4 3 4 1 FRAME SCHEMATIC DIAGRAM SECTION 4 PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS ...