24
9. Plasma Panel Replacement - KZ-42TS1U
b) Seven connectors must be removed. Three connectors have a catch that must be pulled or squeezed to
separate the connector. The remaining four connectors are simply unplugged. Remove the conductive
mesh tape that shields the ribbon connector and unplug the white ribbon cable (Figure 9-3) by pulling it
straight out. Do not fold the ribbon cable.
FIGURE 9-3 - REMOVE 7 CONNECTORS AND 7 SCREWS
Unplug
Connector
7 Machine
Screws
Squeeze
Connector
Pull Catch
Connector
Squeeze
Connector
Ribbon Cable
behind the tape
Circuit Board
Assembly
c) Remove the seven machine screws around the circuit board assembly and pull off the assembly.
d) Remove the rear shield with the top decorative panel to expose the circuitry (Figure 9-4).
FIGURE 9-4 - REAR SHIELD REMOVED
B Board
Power
Supply