2-8. Wire Dressing 1
Ensure that wires do not touch heatsinks and high temperature
hotspots. All wires must be kept at a minimum distance of
20mm away from the EHT lead
20mm
20mm
2-10. Wire Dressing 3
Ensure the RF lead is dressed as shown circled above to avoid
obstructing the rear cover.
2-11. Wire Dressing 4
To avoid damage to the ground interconnecting leads from the
sharp edges of the heatsink they must be dressed as shown
above between the rear of the heatsink and the tuner.
2-9. Wire Dressing 2
The sheathed end of the ground connecting lead must be
plugged into the F3 board to avoid the possibility of the AC
mains power touching ground.