– 48 –
KP-ER43M31/M61/M90/M91, ER53M31/M61/M90/M91
RM-961
5-8. AUTO CONVERGENCE ERROR CODE LIST
If an error code is displayed after the set has been fully adjusted, correctly, plese check the following items : position, tilt and sizing. If
either of these adjustments are off, even slightli, the auto registration pattern will not hit the four sensors properly. This occurs when the
internal generator patterns is being flashed on the screen for the sensor to read. Therefore, auto registration (called auto convergence)
cannot operate properly causing an error code to be displayed. In order for this function to operate properly, correct position, tilt and
size must be adjusted properly.
ERROR CODE LIST
ERROR
DESCRIPTION
NOTE
CODE
00
No Error
10
Sensor Input Level Low
* Check wiring, beam position, sensor.
0 : Upper Center
1 : Middle Left
2 : Middle Right
3 : Lower Center
20
Sensor Input Level High
* Check OP-Amp circuit.
0 : Upper Center
1 : Middle Left
2 : Middle Right
3 : Lower Center
30
Loop Limit Over
* Check the registration information on the convergence board.
40
Regi Data Overflow
* Check the convergence yoke driver ICs.
50
Regi Data Overdraw
60
Offset Data Overflow
* Convergence patterns displayed are out of normal range.
70
Offset Data Overdraw
* : In case of multiple error, last error is displayed.
0 : UPPER SENSOR
1 : LEFT SENSOR
2 : RIGHT SENSOR
3 : LOWER SENSOR
SCREEN
0
3
1
2
[SENSOR POSITION]
PJE
29
140
ERR
|
Category : PJE
Item : 29 ERR
SENSOR NUMBER
ERROR CODE 40
G : 0 (Blank)
R : 1
B : 2
140
• ERROR CODE SCREEN DISPLAY
(When select “PJE”
b
“29 ERR”.)
R, G, B
SENSOR NUMBER
ERROR CODE 10
ERROR
E11B
E11B
• ERROR CODE SCREEN DISPLAY
(When press “
(AUTO CONVERGENCE)” button.)