– 42 –
KP-ER43M31/M61/M90/M91, ER53M31/M61/M90/M91
RM-961
3. PIP 50 Hz (PAL) Mode
1) Enter the PAL SPCB signal, and set in the service mode.
2) Open the remote control cover, press “
(PIP)” button on
the commander to set the PIP mode.
3) Confirm and set the following data.
Condition :
Category
Item
Data
GEO
00
VSZ
01
VPS
02
VLN
03
SCO
04
HSZ
05
HPS
07
PAP
08
UPN
09
LPN
0A
TRZ
0B
AGL
07
0C
BOW
07
15
VSC
1F
MID
00
HPH
3E
01
VPH
15
4) Press “
(MUTE)”+“
-
” buttons on the commander to
write the data to the NVM.
Same as
DRC1250
50 Hz (PAL)
mode
4. TWIN 50 Hz (PAL) Mode
1) Enter the PAL SPCB signal, and set in the service mode.
2) Press “
(TWIN)” button on the commander to set the
TWIN mode.
3) Confirm and set the following data.
Condition :
Category
Item
Data
GEO
00
VSZ
01
VPS
02
VLN
03
SCO
04
HSZ
05
HPS
07
PAP
08
UPN
09
LPN
0A
TRZ
0B
AGL
07
0C
BOW
07
15
VSC
1F
MID
00
HPH
7B
01
VPH
20
11
TMP
01
12
TSP
00
4) Select the category “GEO” and the item “05 HPS”, and ad-
just the horizontal position.
Same as
DRC1250
50 Hz (PAL)
mode
5) Press “
(MUTE)”+“
-
” buttons on the commander to
write the data to the NVM.
H1
H2
H1 – H2 =
±
0.1 sq.