1-1
HVR-DR60
ENGLISH
JAPANESE
ENGLISH
JAPANESE
1. SERVICE NOTE
2.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V),
the power is shut off so that the unit cannot operate.
This following method are available to prevent this.Take note of which to use during repairs.
Method 1.
Use the AC power adaptor.
1-1. SERVICE NOTE
1.
NOTE FOR REPAIR
Make sure that the flat cable and flexible board are not cracked of
bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
Cut and remove the part of gilt
which comes off at the point.
(Take care that there are
some pieces of gilt left inside)
When installing a connector, don’t press down at wire of connector.
Be in danger of the snapping of a wire.
When remove a connector, don’t pull at wire of connector.
Be in danger of the snapping of a wire.