![Sony HKC-7081 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/sony/hkc-7081/hkc-7081_installation-and-maintenance-manual_400559032.webp)
3-8 (E)
HKC-7081
Page
Ver.
Item
Settings
Contents
Knee 1
Point R/G/B/M
_
99 to 99 (
[0]
)
Adjusts the R, G, B or master knee point level when the auto knee
function is turned off
Slope R/G/B/M
_
99 to 99 (
[0]
)
Adjusts the R, G, B or master knee slope level when the auto
knee function is turned off
W.CLP R/G/B/M
_
99 to 99 (
[0]
)
Adjusts the R, G, B or master white clip level
Knee
[On]
, Off
Turns the knee correction circuit on and off
Auto Knee
On,
[Off]
Turns the auto knee function on and off
White Clip
[On]
, Off
Turns the white clip function on and off
Test
[Off]
, 1, 2
Selects the TEST signal
Off: No test signal is output
1:
Outputs the sawtooth waveform test signal
2:
Outputs the 3-step waveform test signal
Clear
Press MENU SEL switch
Resets numeric settings on the Knee 1 page to 0
to execute
(When you press MENU SEL switch, the “Clear” indication flashes.
Press MENU SEL switch again to execute; press CANCEL button
to cancel)
Knee 2
Knee Saturation
On,
[Off]
Turns the knee saturation function on and off
Knee SAT Level
_
99 to 99 (
[_99]
)
Adjusts the knee saturation level
Super Skin Knee
On,
[Off]
Turns on and off the function to improve the color reproduction of
a skin color in a highlight shot scene
Test
[Off]
, 1, 2
Selects the TEST signal
Off: No test signal is output
1:
Outputs the sawtooth waveform test signal
2:
Outputs the 3-step waveform test signal
Clear
Press MENU SEL switch
Resets numeric settings on the Knee 2 page to 0
to execute
(When you press MENU SEL switch, the “Clear” indication flashes.
Press MENU SEL switch again to execute; press CANCEL button
to cancel)
Detail 1
Detail
[On]
, Off
Turns on and off the function to improve resolution by adding the
detail signal
Level
_
99 to 99 (
[_60]
)
Adjusts the master level for the detail signal
Limiter
_
99 to 99 (
[0]
)
Adjusts the clipping level against the maximum detail level
Crispening
_
99 to 99 (
[_25]
)
Adjusts the level at which the detail signal is crispened
H/V Ratio
_
99 to 99 (
[0]
)
Adjusts the mix ratio of H and V detail signals
Frequency
_
99 to 99 (
[0]
)
Adjusts the boost frequency for H detail signal
Level DEP
_
99 to 99 (
[25]
)
Adjusts the level to control the detail signal used at lower signal level
Level DEP
[On]
, Off
Turns the level dependence function on and off
Clear
Press MENU SEL switch
Resets numeric settings on the Detail 1 page to 0
to execute
(When you press MENU SEL switch, the “Clear” indication flashes.
Press MENU SEL switch again to execute; press CANCEL button
to cancel)
3-1. Setup Menu
3-1-2. Paint Menu
Содержание HKC-7081
Страница 1: ...CCD MODIFICATION UNIT HKC 7081 INSTALLATION AND MAINTENANCE MANUAL 1st Edition Revised 1 ...
Страница 6: ......
Страница 42: ......
Страница 68: ......
Страница 70: ......
Страница 74: ......
Страница 80: ......
Страница 82: ......
Страница 84: ......
Страница 85: ...8 7 HKC 7081 8 7 DU 1 DU 1 DU 1 A SIDE SUFFIX 12 DU 1 B SIDE SUFFIX 12 ...
Страница 86: ......
Страница 88: ......
Страница 90: ......