background image

A-6 (E)

HDW-1800/D1800

Page

Button

Name

Factory setting

Setting

P08 : AUD INP

F1

EMPHASIS

OFF

[||]

 ON

[||]

 OFF

F2

 

*

3

AUD MIX

_

_

(

P102)

F3

 

*

4

AUD MONI

_

_

(

P100)

F4

MT.SCALE

FULL

[||]

 FULL

[||]

 FINE

F5

_

F6

AUDIO SG

OFF

[||]

 OFF

[||]

 ON

F7

INP A1

ANA-1

[||]

 SDI-1

[||]

 AES-1

[||]

 ANA-1

F8

INP A2

ANA-2

[||]

 SDI-2

[||]

 AES-2

[||]

 ANA-2

F9

INP A3

ANA-1

[||]

 SDI-3

[||]

 AES-3

[||]

 ANA-1

F10

INP A4

ANA-2

[||]

 SDI-4

[||]

 AES-4

[||]

 ANA-2

*

3: When F2 (AUD MIX) in the function menu page P08 : AUD INP is selected, P102 : AUD MIX is displayed to allow audio mixing setting.

n

Audio mixing setting for the CUE track is available with the setup menu ITEM-833 (CUE AUDIO INPUT SELECT).

Page

Recording track

Factory setting

Setting

P102 : AUD MIX

CH-1

NOT MIX

[||]

 NOT MIX

[||]

 MIX [

[||]

 CH-1 

[||]

 CH-2 

[||]

 CH-3 

[||]

 CH-4]

CH-2

NOT MIX

[||]

 NOT MIX

[||]

 MIX [

[||]

 CH-1 

[||]

 CH-2 

[||]

 CH-3 

[||]

 CH-4]

CH-3

NOT MIX

[||]

 NOT MIX

[||]

 MIX [

[||]

 CH-1 

[||]

 CH-2 

[||]

 CH-3 

[||]

 CH-4]

CH-4

NOT MIX

[||]

 NOT MIX

[||]

 MIX [

[||]

 CH-1 

[||]

 CH-2 

[||]

 CH-3 

[||]

 CH-4]

*

4: When F3 (AUD MONI) in the function menu page P08 : AUD INP is selected, P100 : AUD MONI is displayed to allow audio monitor setting.

n

F5 (TRCK CHG) of the function menu page P100 : AUD MONI is displayed only during playback of MPEG IMX to allow selective setting (CH-5 to CH-8).

Page

Channel monitored

Factory setting

Setting

P100 : AUD MONI

L

CH-1 only

[||]

 CH-1

[||]

 CH-2

[||]

 CH-3

[||]

 CH-4

or

[||]

 CH-5

[||]

 CH-6

[||]

 CH-7

[||]

 CH-8

P101 : AUD MONI

[||]

 CUE

R

CH-1 only

[||]

 CH-1

[||]

 CH-2

[||]

 CH-3

[||]

 CH-4

[||]

 CH-5

[||]

 CH-6

[||]

 CH-7

[||]

 CH-8

[||]

 CUE

Содержание HDW-1800

Страница 1: ...INSTALLATION MANUAL 1st Edition HD DIGITAL VIDEOCASSETTE RECORDER HDW 1800 HDW D1800 ...

Страница 2: ...zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire les risques de décharge électrique d incendie ou de blessure n effectue...

Страница 3: ...abrikat og type Levér det brugte batteri tilbage til leverandøren ADVARSEL Lithiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt batteri returneres apparatleverandøren VARNING Explosionsfara vid felaktigt batteribyte Använd samma batterityp eller en likvärdig typ som rekommenderas av apparattillverkaren Kassera använt batteri enligt gällande fö...

Страница 4: ...does not overload the supply circuit 2 Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack please confirm that the outlet is provided with a suitable protective earth connection 3 Internal air ambient temperature of the rack When this product is installed in a rack please make sure that the internal air ambient temperature of the rac...

Страница 5: ...n Connector Panel 1 14 E 1 10 Switch Settings on Circuit Boards 1 15 E 1 10 1 APR 80 Board 1 15 E 1 11 Operation Mode Settings 1 17 E 1 11 1 Operation Procedure of Destination Selection Mode 1 17 E 1 12 Removing Reattaching Lower Control Panel Unit 1 18 E 1 13 Switching Search Dial Mode 1 19 E 1 14 Reference System 1 20 E 1 15 Settings and Adjustment when External Equipment is Connected 1 21 E 1 1...

Страница 6: ...ion and operation and installation of this unit Maintenance Manual Available on request Volume 1 Service Instruction Volume 2 Parts List Block Diagrams and Board Layouts Volume 3 Schematic Diagrams These manuals describe the maintenace and service information service over view adjustments board layouts schematic diagrams detailed parts list etc for this unit Semiconductor Pin Assignments CD ROM Av...

Страница 7: ...ront and rear of the unit more than 30d c Fix the unit securely to avoid drop when the unit is operat ed at not horizontal place 1 1 Installation Procedure Installation procedure of this unit is shown on the follow ing flowchart Refer to each section about detail of each flow The operation manual is also required to do marked flow 1 3 Operating Conditions 1 4 Power Supply 1 5 Installation Space 1 ...

Страница 8: ...e China 1 Power cord 250 V 10 A 1 8 m 1 783 481 42 2 Plug holder Brown 3 613 640 01 If the unit is used in the area except above please contact your local Sony Sales Office Service Center 1 4 Power Supply 1 4 1 Voltage and Power Requirements This unit s power line has a switching regulator c Be sure to operate the unit within the range of following power voltage Power voltage AC 100 to 240 V 10 Po...

Страница 9: ...possible when operating the unit for inspection with the upper lid re moved If it takes a long time blow to the unit by an electric fan to cool the unit 1 5 Installation Space When installing the installation space must be secured in consideration of the ventilation and service operation Do not block the ventilation slots at the left side and right side panels and vents of the fans Leave a space a...

Страница 10: ...ent toppling over the rack fix it on the horizontal and firm floor securely with bolts etc When installing the unit in an Outside Broadcasting van be sure to fix the unit to the rack using the screws and ornamental washers supplied with the rack mount kit c Use the specified rack mount rail The use of other rail of low strength may drop the unit and cause the risk of injury Mount the unit into a r...

Страница 11: ... arrow A in the figure pull the inner rail out in the direction of the arrow B 6 Remove the ten screws from both sides left and right of the unit as shown in the figure below 7 Attach the two inner rails to both sides left and right of unit with the removed screws in the step 6 Tightening torque 120 x 10_2 N m 12 2 kgf cm m Be sure to use the B4 x 6 screws when attaching the inner rail The use oth...

Страница 12: ...our rail brackets Tightening torque 120 x 10_2 N m 12 2 kgf cm Loosely attaching the rail brackets 10 Slide the intermediate rail as shown in the figure and then loosely attach the rear rail bracket to the outer rail with a plate nut large and the two screws 11 Slide the ball retainer in the direction of the arrow and then loosely attach the front rail bracket to the outer rail with a plate nut la...

Страница 13: ...th of each rail on both sides out 19 Lift the unit holding the gripes on both sides slowly insert the inner rails into the intermediate rails 20 While pressing each stopper of inner rails on both sides slowly push the unit into the rack c Be careful not to catch your finger or hand in rack mount rail n Pushing the unit in the depths of the rack the lock mecha nism prevents the unit from being pull...

Страница 14: ...s fixed to the rack by the lock mechanism Attempt to pull the rack angles and confirm that the unit cannot be pulled out of the rack w When installing the unit in an Outside Broadcasting van be sure to fix the unit to the rack using the screws and ornamental washers supplied with the rack mount kit Tightening torque 120 x 10_2 N m 12 2 kgf cm n When the unit is not fixed to the rack or the clearan...

Страница 15: ...0 651 00 JUNCTION SHEEL 9P 1 561 749 00 RS 232C D SUB 9P FEMALE 1 563 815 21 CONTROL PANEL 20P MALE 1 833 620 11 exclusive connecting cable VIDEO CONTROL 9P D SUB 9P MALE and 1 561 651 00 JUNCTION SHELL 9P 1 561 749 00 HDV IN OPTION Specified by optional kit _ HD SDI BNC 75Z MALE 2 1 569 370 12 SDI BNC 75Z MALE 3 1 569 370 12 PHONES JM 60 stereo phone plug _ Upper control panel connector 1 Coaxial...

Страница 16: ...nc HD 0 6 V p p 75 Z sync negative Ternary SYNC 3 AUDIO INPUT AES EBU BNC x 2 1 set CH1 2 CH3 4 Digital audio AES EBU format complies with AES 3id 1995 5 HD SDI INPUT BNC x 1 Serial digital interface 1 485 Gbit s complies with SMPTE 292M 6 HDV IN OPTION i LINK 6 pin x 1 Complies with IEEE1394 Remote connectors 4 REMOTE 2 PARALLEL I O 50P D SUB 50P connector 4 REMOTE1 IN 9P D SUB 9P connector RS 42...

Страница 17: ... 1 0 V p p 75 Z sync negative 3 AUDIO OUTPUT AES EBU BNC x 4 1 set CH1 2 CH3 4 CH5 6 and CH7 8 or BNC x 2 1 set CH1 2 CH3 4 Digital audio AES EBU format complies with AES 3id 1995 5 HD SDI OUTPUT BNC x 3 including 1 for character superimpose Serial digital interface 270 Mbit s complies with SMPTE 292 5 SDI OUTPUT BNC x 3 including 1 for character superimpose Serial digital interface 270 Mbit s com...

Страница 18: ...NESS TAPE THICKNESS STATUS 14 OUT X SPARE SPARE 15 OUT X SPARE SPARE 16 12V Maximum output current 50 mA 17 GND SIGNAL GND 18 IN O PREROLL CLOSURE SW PREROLL 19 IN O STBY ON CLOSURE SW STANDBY ON 20 IN O REW CLOSURE SW REW 21 IN O ENTRY CLOSURE SW ENTRY IN 22 IN O STBY OFF CLOSURE SW STANDBY OFF 23 IN O EJECT CLOSURE SW EJECT 24 OUT X REC REC STATUS 25 OUT X CH CONDITION RED CHANNEL CONDITION RED ...

Страница 19: ... X REMOTE REMOTE STATUS 49 OUT X ALARM SYSTEM ALARM STATUS 50 OUT O PREROLL PREROLL STATUS 1 Input 47 kZ pull up to 5 V close open Output 10 kZ pull up to 5 V 0 V or open 2 The pins described as O mark are possible to change the setting Refer to the optional interface manual for changing the setting RS 232C 9 pin male REMOTE1 IN 9 pin female REMOTE1 OUT 9 pin female Pin No Signal 1 GND 2 RM TX _ 3...

Страница 20: ...2 VG 3 NTPB 4 TPB 5 NTPA 6 TPA 1 9 Switch Settings on Connector Panel When the unit is installed be sure to perform the following setup Refer to the operation manual Section 2 Location and Function of Parts for setup Analog audio input level 600 Z termination switches 75 Z termination switch of reference video input External view 1 5 9 6 External view 1 3 5 2 4 6 ...

Страница 21: ... APR 80 board Audio input output and monitor output Audio input reference level Audio output reference level Monitor output reference level Monitor output level fixed variable selection n Refer to Section 1 16 for removing and reattaching the plug in boards Top View APR 80 Board Side A A A B C D E F G H J K L APR 80 M P S1901 S1900 S1902 S2001 S2000 N 1 2 3 4 5 6 ...

Страница 22: ...ition S1902 7 8 4 dBm 600 Z 0 dBm 600 Z _3 dBm 600 Z _20 dBm 600 Z Factory setting Monitor output level switching fixed or variable When the variable level is selected the level is adjusted with the PHONES level control knob Channel Ref No Switch state Knob position L S2001 Fixed Variable R S2000 Factory setting Factory use n Never change the setting Ref No Switch state S1900 S1901 All OFF O N 1 2...

Страница 23: ...f Destination Selection Mode 1 When no destination has not been selected turning on the POWER switch displays the following indication in the menu display area of the control panel 2 Pressing the F3 _ or F4 button selects the destination 50 SYL 59 94 SYL or 59 94 J 3 Press the F9 SET button Pressing the F9 SET button accepts the selected destination Screen 2 appears after Screen 1 is displayed for...

Страница 24: ...re BVTT3 x 6 BVTT3 x 6 POWER O I Lower control panel unit Unlock button Unlock button Cable Cable holder Connector Power OFF Back view Lower control panel unit 5 Lightly draw the lower control panel unit toward you and then lift it upward Reattaching Reattach the lower control panel unit in the reverse order of removal Yet when reattaching use care about following points If the arms are not open p...

Страница 25: ...he jog mode press the JOG button To enter the variable mode press the VAR button Search dial pressing When you press the search dial the search dial mode switches in order to shuttle jog variable It is possible to prohibit a manner of switching Prohibiting Search Dial Pressing 1 After pressing the unlock buttons open the lower control panel as shown in the figure below 2 Loosen a screw on the back...

Страница 26: ... external reference video signal for the period in which the no input video signal is input When no external reference video signal is input the internal generated reference signal is automatically selected for the period An audio signal can be independently recorded by this system even if no reference video signal is input from the outside Alarm Display for Video Input Signal and Reference Signal...

Страница 27: ...Editor Set the VTR constant values according to the table 1 15 2 below when the editor which needs the setting of VTR constant values is connected Moreover the change of VTR constant values are required when the operation mode is switched by setup menu of this unit n When remote controlling this unit by the editor set the setup menu ITEM 401 FUNCTION MODE AFTER CUE UP to STOP Table 1 15 2 VTR Cons...

Страница 28: ...an Analog Switcher Perform the system phase adjustment according to the manual of the analog switcher To adjust the system phase of this unit use the MULTI CONTROL knob at the P03 VID PROC page on the function menu When adjusting i e changing the settings press the button below to blink the current setting value and then turn the MULTI CONTROL knob Button Item Display F3 SYSTEM SYNC PHASE SYNC PHS...

Страница 29: ...rd to the connector on the motherboard When reattaching the upper lid rear assembly be sure to insert the protrusions in the square holes on the chassis and then secure the lid 1 17 Taking Out the Cassette in Tape Slacking When slacking the tape in this unit follow the steps below to take out the cassette tape n Being careful not to damage the tape take out the cassette tape with care 1 Turn off t...

Страница 30: ...ape 7 Pull the ME wire for a few times with short steps to take up the tape inside the cassette m Be careful for the tape not to catch in parts such as a flange of a tape guide Don t take the ME wire off the wire holder The ME wire links with the T real table The T real table rotates about 1 24 turns clockwise take up direction by pulling the ME wire about 6 mm 8 Rotate the M gear of the threading...

Страница 31: ...ing error Model name Serial No _____________________________ Firmware SY1 ROM version ____________________________ SY2 ROM version ____________________________ SV ROM version ____________________________ RS 232C baud rate bps Hours meter Write down the value of hours meter when checking servicing and maintaining ITEM Date Hours meter H01 OPERATION HOURS H02 DRUM RUNNING HOURS H03 TAPE RUNNING HOUR...

Страница 32: ... setting of Factory use switches Board Name Channel Switch No Factory setting Setting AE 31 Factory use CH1 S100 All OFF _ HEAD TUNE switch CH2 S200 All OFF _ APR 80 Audio input output and monitor CH1 2 L R S1902 20 dB 20 18 16 12 output headroom Audio input reference level CH1 2 S1902 4 dBm 600 Z 4 0 _3 _20 Audio output reference level CH1 CH2 S1902 4 dBm 600 Z 4 0 _3 _20 Monitor output reference...

Страница 33: ...DISABLE OFF S1501 Never change the settings of S1501 switch since each switch is set according to the characteristics of the unit 1 Factory use OFF _ 2 6 Model ID switch See below _ 7 J SY ON _ 8 525 625 OFF S1502 1 EXTENDED MENU ON 2 MAINTENANCE MODE ACCESS ENABLE ON 3 8 Factory use OFF _ S1501 factory setting Knob position ON HDW 1800 1 8 ON HDW D1800 1 8 ...

Страница 34: ... LTC AUTO VITC P03 VID PROC F1 VIDEO IN SDI SDI SG F2 REF VID INPUT REF INPUT F3 SYNC PHS 0 VALUE _______ F4 SYCN FIN 0 VALUE _______ F5 V PROC LOCAL LOCAL MENU F6 VID LEVL PRESET PRESET VALUE _______ F7 CHR LEVL PRESET PRESET VALUE _______ F8 1 HUE CHR PHAS PRESET PRESET VALUE _______ F9 2 SETUP LV BLK LEVL PRESET PRESET VALUE _______ F10 PRESET _ _ P04 MISC 1 F1 CAPSTAN 4F 2F 4F 8F F2 _ F3 PRERE...

Страница 35: ..._ F9 FRZOFF _ _ F10 _ P06 EDIT F1 AUTOEDIT _ _ F2 PREVIEW _ _ F3 REVIEW _ _ F4 DMC _ _ F5 PREROLL _ _ F6 R P SEL OFF OFF RECDER PLAYER F7 AUD IN _ _ F8 AUD OUT _ _ F9 IN _ _ F10 OUT _ _ P07 E PRESET F1 REC INHI OFF ON OFF F2 INS TC _ _ F3 INS CUE _ _ F4 EDIT _ _ F5 ASSEMBLE _ _ F6 INS VID _ _ F7 INS A1 _ _ F8 INS A2 _ _ F9 INS A3 _ _ F10 INS A4 _ _ ...

Страница 36: ...enu ITEM 833 CUE AUDIO INPUT SELECT Page Recording track Factory setting Setting P102 AUD MIX CH 1 NOT MIX NOT MIX MIX CH 1 CH 2 CH 3 CH 4 CH 2 NOT MIX NOT MIX MIX CH 1 CH 2 CH 3 CH 4 CH 3 NOT MIX NOT MIX MIX CH 1 CH 2 CH 3 CH 4 CH 4 NOT MIX NOT MIX MIX CH 1 CH 2 CH 3 CH 4 4 When F3 AUD MONI in the function menu page P08 AUD INP is selected P100 AUD MONI is displayed to allow audio monitor setting...

Страница 37: ...été de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrückli...

Страница 38: ...Printed in Japan Sony Corporation 2006 9 08 2006 HDW 1800 SY HDW 1800 CN HDW D1800 SY HDW D1800 CN J E 3 992 809 01 ...

Отзывы: