152
Menu List
App
endi
x
Items Relating to the Time Code (Nos. 601 to ...)
503
TAPE
PROTECTION
MODE FROM STOP
[standby off]
tension release
Specifies the tape-protect mode to which the VTR changes
to from the stop mode.
The unit automatically enters the specified tape-protect
mode after the elapse of time specified by item 501.
standby off: The VTR enters standby off mode (standby is
canceled).
tension release: The VTR enters tension release mode
(tape tension is released).
504
DRUM ROTATION
IN STANDBY OFF
[off]
on
Sets the drum rotation to “on” or “off” during standby-off
mode.
off: Drum rotation is stopped.
on: Drum rotation continues.
505
STILL TENSION
[normal]
loose
Sets the tape tension control in still-picture mode.
normal: Maintains the tape tension that ensures unaffected
playback even in still-picture mode.
(This is the normal setting for VTR operations.)
loose: Sets the tape tension lower than that of the “normal”
setting after the VTR enters still-picture mode.
506
DRUM ROTATION
TIMER
1 min
2 min
3 min
4 min
5 min
10 min
15 min
30 min
1H
2H
3H
[4H]
8H
When menu item 502 or 503 set to “tension release”, or
when menu item 504 is set to “on”, the drum motor of this
unit continues to rotate after tension release mode is
entered.
This menu item sets the time until the unit enters standby
off mode and the drum motor stops rotating after entering
tension release mode.
The selectable time ranges from one minute to eight hours.
Item number
Item
Setting
Function
601
DF/NDF MODE
select
[drop frame]
non-drop frame
auto
Selects the timing mode for the time code generator and
the CTL counter.
drop frame: drop frame mode (“DF” indication)
non-drop frame: non-drop frame mode (“NDF” indication)
auto: Drop frame / non-drop frame mode is selected
automatically on the basis of the frame frequency of
the unit. For 29.97 Hz/59.94 Hz drop frame mode is
selected, and for 30 Hz/60 Hz non-drop frame mode is
selected. The setting of the frame frequency mode is
carried out with the
[F9]
(OTHERS CHECK)/
[F9]
(SYSTEM) button in MAINTENANCE menu.
Notes
• This setting is only active when the frame frequency of
the unit is 29.97 Hz, 59.94 Hz, 30 Hz, or 60 Hz.
• When the
[F7]
(TCG MODE) key is set to “regene” in TC
menu, the time code generator is synchronized to the
playback time code, and therefore this setting is disabled.
Item number
Item
Setting
Function