20
HCD-GX470/GX570
SECTION 5
MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer. (Do not bring the head magnetizer close to the
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, appiy suitable locking compound to
the parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
TORQUE MEASUREMENT
Mode
Torque Meter
Meter Reading
2.6 – 6.9 mN
⋅
m
FWD
CQ-102C
(30 – 70 g
⋅
cm)
(0.41 – 0.97 oz
⋅
inch)
FWD
0.15 – 0.59 mN
⋅
m
Back Tension
CQ-102C
(1.5 – 6.0 g
⋅
cm)
(0.021 – 0.083 oz
⋅
inch)
5.4 – 16.7 mN
⋅
m
FF/REW
CQ-201B
55 – 170 g
⋅
cm)
0.76 – 2.35 oz
⋅
inch)
TAPE TENSION MEASUREMENT
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 100 g
(more than 3.53 oz)
Содержание HCD-GX470