SECTION 3
TEST MODE
COLD RESET (MAIN UNIT)
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the unit to
the customers.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Touch the [
x
] and [VOL –] sensors simultaneously and hold
down (around 5 seconds).
3. The message “RESET” appears on
fl
uorescent indicator tube,
then becomes standby states.
COLD RESET (SURROUND AMPLIFIER)
(HBD-N790W/N890W/N990W/N995W/T79 only)
Execute this mode when returning the unit to the customers.
Note 1:
The main unit corresponding to TA-SA300WR, wireless trans-
ceivers (EZW-RT50 (HBD-N790W/N890W/N990W/T79) or
EZW-RT20 (HBD-N995W)) (2 units) and the remote command-
er corresponding to the main unit are necessary to execute this
mode.
Procedure:
1. Insert the wireless transceiver (EZW-RT50 (HBD-N790W/
N890W/N990W/T79) or EZW-RT20 (HBD-N995W)) of the
attachment in the wireless transceiver slot in the back of the
main unit (HBD-N790W/N890W/N990W/N995W/T79) and
the surround ampli
fi
er (TA-SA300WR).
Wireless
transceiver
(EZW-RT50 (HBD-N790W/
N890W/N990W/T79) or
EZW-RT20 (HBD-N995W))
Wireless
transceiver
(EZW-RT50 (HBD-N790W/
N890W/N990W/T79) or
EZW-RT20 (HBD-N995W))
EZW
-RT50
Rear panel of the main unit
(HBD-N790W/N890W/N990W/N995W/T79)
Rear panel of the surround amplifier
(TA-SA300WR)
2. Connect the AC power cord of the main unit (HBD-N790W/
N890W/N990W/N995W/T79).
3. Press the [
\/1
] button on the main unit (HBD-N790W/
N890W/N990W/N995W/T79).
4. Connect the AC power cord of the surround ampli
fi
er (TA-
SA300WR).
5. When a wireless transceiving becomes effective, the [LINK/
STANDBY] indicator of surround ampli
fi
er (TA-SA300WR)
lights to green.
Note
2:
Refer to the operating instructions when the [LINK/STAND-
BY] indicator of surround ampli
fi
er (TA-SA300WR) doesn’t
light.
LINK/STANDBY indicator
.+0-56#0&$;
6. Press the button in order of the [DISPLAY]
[0]
[7]
[2]
[SUBTITLE] on the remote commander corresponding to
main unit aiming at the main unit.
7. Con
fi
rm the [LINK/STANDBY] indicator of TA-SA300WR is
orange lighting after step 3 is executed.
8. The AC plug of TA-SA300WR is pulled out to turn off the
system.
Note
3:
Please insert it after con
fi
rming the [LINK/STANDBY] indi-
cator of TA-SA300WR has been turned off when you insert
the AC plug again.
DEMO MODE
This mode let you lock the disc slot. When this mode is activated,
the disc will not eject when the [
Z
] sensor is touched. The mes-
sage “DEMO LOCK” will be displayed on the fluorescent indica-
tor tube.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Insert a disc.
3. Press the [HOME] button on the remote commander to enter
the home menu.
4. Touch the [
x
] and [
Z
] sensors simultaneously and hold down
until “DEMO.LOCK” or “DEMO OFF” displayed on the fluo-
rescent indicator tube (around 5 seconds).
Releasing method:
Touch the [
x
] and [
Z
] sensors simultaneously and hold down until
“DEMO OFF” displayed on the
fl
uorescent indicator tube (arround
5 seconds).