1-4
FDR-AX100/AX100E/HDR-CX900/CX900E_L2
– ENGLISH –
approx. 330 msec
Note:
The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of R1802 on the VC-1027 board
1-7-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R1802 in the periphery of IC1802 on the VC-1027 board, turn the
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
the camera control circuit (IC6000 of VC-1027 board) periphery.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-7-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred
Order
Procedure
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SERVICE] tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage of C1824 and C1828 in the periphery of IC1802 on the VC-
1027 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of R1802 in the periphery of IC1802 on the VC-1027 board, turn the power
ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
7
If the output voltage rises to 3V, replace the lens block (Note).
If it does not rises to 3V, inspect the camera control circuit (IC6000 and IC1802 of VC-1027 board) periphery.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-7-3.E : 62 : 12 [Shift Lens Overheating (Yaw)] Occurred
Order
Procedure
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SERVICE] tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage of C1820 and C1822 in the periphery of IC1802 on the VC-
1027 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of R1802 in the periphery of IC1802 on the VC-1027 board, turn the power
ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
7
If the output voltage rises to 3V, replace the lens block (Note).
If it does not rises to 3V, inspect the camera control circuit (IC6000 and IC1802 of VC-1027 board) periphery.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-7-4. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
Procedure
1
Turn the power ON.
2
Confirm the connections of flexible flat cables and connectors between the lens block and VC-1027 board.
3
In case of no malfunction of connections, replace the lens block with new one (Note) . When the error has occurred in spite of the lens
replacement, replace VC-1027 board with new one.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.