5-19
GV-D1000/D1000E
6.7 msec
PB RF signal is stable
Pin
qj
Pin
w;
Fig. 5-3-4.
4-2. AGC Center Level Adjustment (VC-275 board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Pin
w;
of CN933 (RF MON) (Note 1)
Ext. trigger: Pin
qj
of CN933 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1E
Specified Value
The data of page: 3, address: 03 is
“00”
Note1:
Connect a 75
Ω
resistor between Pin
w;
and Pin
ql
(GND) of
CN933.
75
Ω
resistor (Parts code: 1-247-804-11)
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before
adjustments”
2
0
01
01
Set the data.
3
3
33
08
Set the data.
4
Confirm that the playback RF
signal is stable. (Fig. 5-3-4.)
5
3
01
23
Set the data, and press PAUSE
button.
6
3
02
Check that the data is “00”.
7
3
03
Check that the data is “00”.
(Note2)
8
Perform “APC & AEQ
Adjustment”.
Note2:
If the data of page: 3, address: 03 is other than “00”, adjustment
has errors. (Take an appropriate remedial measures according to
the errors referring to the following table.)
Data
Contents of defect
20
Perform re-adjustment. (Note 3)
30
The machine is defective
40
Perform re-adjustment. (Note 3)
50
The machine is defective
Note3:
If this data is displayed twice successively, the machine is defective.
4-3. APC & AEQ Adjustment (VC-275 board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Pin
w;
of CN933 (RF MON) (Note 1)
Ext. trigger: Pin
qj
of CN933 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 2C
Specified Value
The data of page: 3, address: 03 is
“00”
Note1:
Connect a 75
Ω
resistor between Pin
w;
and Pin
ql
(GND) of
CN933.
75
Ω
resistor (Parts code: 1-247-804-11)
Note2:
The “AGC Center Level Adjustment” must have already been
completed before starting this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before
adjustments”
2
0
01
01
Set the data.
3
3
33
08
Set the data.
4
Confirm that the playback RF
signal is stable. (Fig. 5-3-5.)
5
3
01
07
Set the data, and press PAUSE
button.
6
3
02
Check that the data changes
from “07” to “00” in about 20
seconds after pressing PAUSE
button.
7
3
03
Check that the data is “00”.
(Note3)
8
Perform “Processing after
Completing Adjustments”.
Note3:
If the data is other than “00”, adjustment has errors. Take an
appropriate remedial measures according to the errors referring to
the following table.
Data
Contents of defect
20
Perform re-adjustment. (Note 4)
30
The machine is defective
50
Perform re-adjustment. (Note 4)
60
The machine is defective
80
The machine is defective
Note4:
If this data is displayed twice successively, the machine is defective.
Fig. 5-3-5.
6.7 msec
PB RF signal is stable
Pin
qj
Pin
w;
Содержание GV-D1000E - Digital Video Cassette Recorder
Страница 55: ...Schematic diagram of the MS 95 board are not shown Pages from 4 43 to 4 52 are not shown ...
Страница 66: ...Printed wiring board of the MS 95 board are not shown Pages from 4 71 to 4 72 are not shown ...
Страница 70: ...Waveforms of the MS 95 board are not shown Page 4 76 is not shown ...
Страница 74: ...Mounted parts location of the MS 95 board is not shown Page 4 80 is not shown ...
Страница 75: ...5 1 GV D1000 D1000E SECTION 5 ADJUSTMENTS COVER COVER ...
Страница 133: ...GV D1000 D1000E 176 Sony EMCS Co 2002A1600 1 2002 1 Published by DI Customer Center 9 929 929 31 ...
Страница 134: ...Revision History Ver 1 0 Date 2002 01 History Official Release Contents S M Rev issued 992992931 pdf Reverse ...