
5-14
GV-D1000/D1000E
3-2-3.
INITIALIZATION OF B PAGE DATA
Note1:
When reading the B page data, insert a “Memory Stick” into the
“Memory Stick” slot.
Note2:
“INITIALIZATION OF B PAGE DATA” should be carried out
upon completion of “INITIALIZATION OF C, D, 8 PAGE DATA”.
1. Initializing the B Page Data
Note:
If the B page data has been initialized, the following adjustments
need to be performed again.
1) Modification of B page data
Adjusting page
B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
10
05
Set the data, and press PAUSE
button.
3
2
8F
02
Set the data, and press PAUSE
button.
4
2
8F
03
Set the data, and press PAUSE
button.
5
2
8F
02
Set the data, and press PAUSE
button.
6
2
8F
00
Set the data, and press PAUSE
button.
7
5
0E
00
Set the data.
8
5
01
F3
Set the data, and press PAUSE
button.
9
5
00
01
Set the data, and press PAUSE
button.
10
Wait for 3 sec.
11
5
0E
Check that the data is “01”.
12
5
02
01
Set the data, and press PAUSE
button.
13
5
01
FE
Set the data, and press PAUSE
button.
14
5
00
01
Set the data, and press PAUSE
button.
15
5
02
Check that the data.
When the data is “00”, proceed
to step 20.
When the data is “FF”, proceed
to step 16.
16
2
0E
00
Set the data, and press PAUSE
button.
17
5
01
FD
Set the data, and press PAUSE
button.
18
5
00
01
Set the data, and press PAUSE
button.
19
5
0E
Check that the data is “01”.
20
Perform “Modification of B Page
Data”.
2. Modification of B Page Data
If the B page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Preparations:
Order Page Address Data
Procedure
1
0
01
01
Set the data, and press PAUSE
button.
2
D
10
05
Set the data, and press PAUSE
button.
3
2
8F
02
Set the data, and press PAUSE
button.
4
2
8F
03
Set the data, and press PAUSE
button.
5
2
8F
02
Set the data, and press PAUSE
button.
6
2
8F
00
Set the data, and press PAUSE
button.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the video cassette
recorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
10
00
Set the data.
3
2
00
29
Set the data.
4
2
01
29
Set the data, and press PAUSE
button.
3. B Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B Page
Data”).
Table. 5-3-9.
Address
Remark
00 to FF
Fixed data-1
Содержание GV-D1000E - Digital Video Cassette Recorder
Страница 55: ...Schematic diagram of the MS 95 board are not shown Pages from 4 43 to 4 52 are not shown ...
Страница 66: ...Printed wiring board of the MS 95 board are not shown Pages from 4 71 to 4 72 are not shown ...
Страница 70: ...Waveforms of the MS 95 board are not shown Page 4 76 is not shown ...
Страница 74: ...Mounted parts location of the MS 95 board is not shown Page 4 80 is not shown ...
Страница 75: ...5 1 GV D1000 D1000E SECTION 5 ADJUSTMENTS COVER COVER ...
Страница 133: ...GV D1000 D1000E 176 Sony EMCS Co 2002A1600 1 2002 1 Published by DI Customer Center 9 929 929 31 ...
Страница 134: ...Revision History Ver 1 0 Date 2002 01 History Official Release Contents S M Rev issued 992992931 pdf Reverse ...