5-10
GV-D1000/D1000E
3-2-2.
INITIALIZATION OF C, D, 8 PAGE DATA
1. Initializing the C, D, 8 Page Data
Note1: If “Initializing the C, D, 8 Page Data” is performed, all
data of the C page, D page and 8 page will be initialized.
(It is impossible to initialize a single page.)
Note2:
If the C, D, 8 page data has been initialized, the following
adjustments need to be performed again.
1) Modification of C, D, 8 page data
2) Serial No. input
3) Servo and RF system adjustments
4) Video system adjustments
5) LCD system Adjustments
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to FF
Adjusting page
8
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data
2
3
81
Check that the data is “00”.
3
3
80
0A
Set the data, and press the PAUSE
button.
4
3
80
Check that the data changes to
“1A”
5
C
43
10
Set the data, and press the PAUSE
button.
6
Perform “Modification of C, D, 8
Page Data”.
2. Modification of C, D, 8 Page Data
If the C, D, 8 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the video cassette
recorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C, D, 8 Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of C, D, 8 page data”, check that the data of the “Fixed
data-2” addresses of D page are same as those of the same model of
the same destination.
1) The battery end mark on the LCD or viewfinder screen is flashing.
2) The power is shut off so that unit cannot operate.
3. C Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”).
00 to 0F
10
11
12
13
14 to 15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
26
27
28
29
2A to 2B
2C
2D to 41
42
43
44
45
46
47 to 4B
4C
4D
4E to 4F
50
51
52 to 75
76
77
78
79
7A
7B to 83
84
85
EE
00
00
00
E0
2A
2A
32
32
25
3E
3E
DC
99
88
E3
A1
04
20
03
10
Switching position adj.
Fixed data-1
Cap FG duty adj.
Fixed data-2
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Chroma BPF fo adj.
PLL fo fine adj.
Fixed data-1
APC adj.
Fixed data-1
Fixed data-2
Fixed data
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Содержание GV-D1000E - Digital Video Cassette Recorder
Страница 55: ...Schematic diagram of the MS 95 board are not shown Pages from 4 43 to 4 52 are not shown ...
Страница 66: ...Printed wiring board of the MS 95 board are not shown Pages from 4 71 to 4 72 are not shown ...
Страница 70: ...Waveforms of the MS 95 board are not shown Page 4 76 is not shown ...
Страница 74: ...Mounted parts location of the MS 95 board is not shown Page 4 80 is not shown ...
Страница 75: ...5 1 GV D1000 D1000E SECTION 5 ADJUSTMENTS COVER COVER ...
Страница 133: ...GV D1000 D1000E 176 Sony EMCS Co 2002A1600 1 2002 1 Published by DI Customer Center 9 929 929 31 ...
Страница 134: ...Revision History Ver 1 0 Date 2002 01 History Official Release Contents S M Rev issued 992992931 pdf Reverse ...