2-6.
Precaution on Replacing the LD-1017 Board
2-6-1.
Angular Velocity Sensor
Before replacing the board with a repairing board, be sure to record the sensitivity indicated on the angular velocity
sensor on the repairing board.
The recorded sensitivity indication must be stored in the repairing board.
Method of the angular velocity sensor sensitivity writing:
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj” on the
ADJUST tab.
Note
The sensitivity of the angular velocity sensor is indicated only on the repairing board, but is not indicated on mass
production boards.
FDR-AX30/FDR-AX33/FDR-AXP33/FDR-AXP35