SELF-DIAGNOSTIC FUNCTION
Display of Standby/Timer LED Flash Count
Diagnostic items
Flash count
Lamp OFF 3 sec.
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
+B Overcurrent
2 times
Low +B Overvoltage
3 times
Vert. Deflection Stopped
4 times
White Balance Failure
5 times
Low +B OCP/OVP
6 times
Horiz. Deflection Stopped
7 times
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LAMP from
fl
ashing.
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to
fl
ash. The number
of times the LED
fl
ashes translates to a probable source of the problem. A de
fi
nition of the STANDBY/TIMER LED
fl
ash indicators is listed in the
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will
fl
ash a set number of times to indicate the possible cause of the problem. If there is more than
one error, the LED will identify the
fi
rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, an error has occurred.
Diagnostic Item
No. oftimes
STANDBY /
TIMER lamp
flashes
Display
Result
Probable Cause Location
Detected Symptoms
Power does not turn on
Does not light
_______
•
Power cord is not plugged in.
•
Fuse is burned out (F501). (A Board)
•
Power does not come on.
•
No power is supplied to the TV.
•
AC Power supply is faulty.
+B Overcurrent (OCP)*
2 times
2:0 or 2:1
•
H.OUT (Q5030) is shorted. (D Board)
•
+B PWM (Q5003) is shorted.
(D Board)
•
Power does not come on.
•
Load on power line shorted.
Low +B Overvoltage (OVP)
3 times
3:0 or 3:1
•
IC6505 is faulty. (D Board)
•
Has entered standby mode.
Vertical Deflection Stopped
4 times
4:0 or 4:1
•
15Vis not supplied. (D Board)
•
IC5004 is faulty. (D Board)
•
Has entered standby mode after
Horizontal raster.
•
Vertical deflection pulse is stopped.
•
Power line is shorted or power
supply is stopped.
White Balance Failure
(not balanced)
5 times
5:0 or 5:1
•
Video OUT (IC9001-IC9003) is faulty.
(CH, CX Board)
•
CRT drive (IC2801) is faulty. (B Board)
•
G2 is improperly adjusted.**
•
No raster is generated.
•
CRT cathode current detection
reference pulse output is small.
LOW +B OCP/OVP
(overcurrent/overvoltage)***
6 times
6:0 or 6:1
•
+5 line is overloaded. (A, B, M Boards)
•
+5 line is shorted. (A, B, M Boards)
•
IC504 is faulty. (A Board)
•
No picture
Horizontal Deflection
Stopped
7 times
7:0 or 7:1
•
No picture
* If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first by the
microcontroller is displayed on the screen.
** Refer to Screen (G2) in Section 2-5 of this manual.
*** If STANDBY/STEREO LED flashes six (6) times, unplug the unit and wait 10 seconds before performing the adjustment.
Self Diagnosis
Supported model
Standby/Timer LED
* One
fl
ash count is not used for
self-diagnostic.
Содержание FD Trinitron WEGA KV-36HS500
Страница 23: ... 23 KV 32HS500 32HV600 34DRC500 34XBR800 36HS500 36XBR800 38DRC500 40XBR800 42DRC800 3 3 HV SERVICE FLOWCHART ...
Страница 346: ......
Страница 347: ......
Страница 348: ......
Страница 349: ......
Страница 350: ......
Страница 351: ......
Страница 352: ......
Страница 416: ...3 3V al Input 9 965 925 02 DA4 B 6 6 ...