0
Basic Functions
FCB-EH6500(GB) A-EEP-100-11(1)
Motion Detection (MD) Function
This function instructs the camera to detect movement
within the monitoring area and then send an alarm
signal automatically.
The Detect signal goes out through the serial command
(VISCA) communication line.
Features
• You can set a frame for the detection range of
16 (horizontally) × 8 (vertically) blocks.
• You can set up to four frames.
• When the motion is detected in the set frame, the
Alarm Replay VISCA command is sent.
• The threshold level for detection can be set (common
to four frames).
• The interval of alarm detection can be set up to
255 seconds in units of one second.
• You can set on/off for each frame.
• The frame number is also sent with Alarm Replay to
report in which frame the motion has been detected.
Frames
Setting frames
You can set the frame by assigning the starting point
and terminating point vertically and horizontally. You
can set up to four frames.
When motion is detected within the rage where
frames overlap
The alarms are sent for both frames.
At this position, the
alarm for frame 3 is
sent.
Within this overlapped
range, alarms are sent for
both frame 3 and frame 4.
Frame 1
Frame 2
Frame 3
Frame 4
Non Interlock Mask
Command:
8x 01 04 6F mm 0p 0p 0q 0q 0r 0r 0s 0s
FF
Parameters:
mm Setting Mask
See “mm: Mask setting list” in “Parameters” on page 18.
pp
Sets the center position “x” of the Mask on screen.
Sets the center position “y” of the Mask on screen.
rr
Sets the half value “w” of the Mask Width.
ss
Sets the half value “h” of the Mask Height.
See “pp: x, qq: y, rr: w, ss: h” in “Parameters” on page 18.
Commands:
Mask does not interlock with pan/tilt.
The limitations of parameters are as follows.
(hexadecimal representation)
x: ±50h
w: ±50h
y: ±2Dh
h: ±2Dh
Note
When the Set Mask command and the Non Interlock Mask
command are set to the same mask, the command set later
becomes effective.
Grid
Use the grid displayed on the screen to set mask
positions (see the figure below).
By executing the Center Line On command, only the x
and y axes of the center are displayed. Grids lines
disappear.
Содержание FCBEH6500
Страница 1: ... 2012 Sony Corporation Color Camera Module FCB EH6500 A EEP 100 11 1 Technical Manual ...
Страница 57: ...57 Specifications DIGITAL Image Output Y Cb Cr 4 2 2 FORMAT Color coding complies with BT709 ...
Страница 58: ...58 Specifications Timing Chart 1080i 60 Output Timing Chart CLK VD HD Data 1080i 50 Output Timing Chart ...
Страница 59: ...59 Specifications 1080p 30 Output Timing Chart 1080p 25 Output Timing Chart ...
Страница 60: ...60 Specifications 720p 60 Output Timing Chart 720p 50 Output Timing Chart ...
Страница 61: ...61 Specifications 720p 30 Output Timing Chart 720p 25 Output Timing Chart ...