background image

 

 

 

 

 

VC-BC601P 

HD Camera 

(FHD Box Camera) 

 

 

 
 

 

 

 
 
 

      [Important] 

 

 

 

 

 

User Manual - English 

To download the latest version of Quick Start Guide, 

multilingual user manual, software, or driver, etc., 

please visit Lumens 

https://www.MyLumens.com/support

 

Summary of Contents for VC-BC601P

Page 1: ...1P HD Camera FHD Box Camera Important User Manual English To download the latest version of Quick Start Guide multilingual user manual software or driver etc please visit Lumens https www MyLumens com support ...

Page 2: ... 1 I O functions Introduction 6 3 2 Tally Indicator Light Function Description 7 Chapter 4 Instruction for installation 8 4 1 Basic Devices 8 4 2 Connecting devices 9 Chapter 5 Network Function Settings Description 11 5 1 Web System Requirements 11 5 2 Connecting Camera to Network 11 5 3 Web Page Function Description 15 Chapter 6 Troubleshooting 27 ...

Page 3: ... product Lumens Digital Optics Inc hereby reserves the right to make changes to product specifications without prior notice The information in this file is subject to change without prior notice To fully explain or describe how this product should be used this manual may refer to names of other products or companies without any intention of infringement Disclaimer of warranties Lumens Digital Opti...

Page 4: ...rsonnel 1 11 Unplug the product from the wall outlet and refer servicing to licensed service personnel when the following situations happen If the power cords are damaged or frayed If liquid is spilled into the product or the product has been exposed to rain or water 2 Installation 2 1 For security considerations please make sure the standard hanging rack you bought is in line with UL or CE safety...

Page 5: ...e limits are designed to provide reasonable protection against harmful interference in a commercial installation This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of Industry Canada Cet appareil numerique respecte les limites de bruits radioelectriq...

Page 6: ...English 5 Chapter 2 Package Contents VC BC601P Power Cord Power Adapter Appearance may vary depending on country region Instruction for installation Quick Installation Guide ...

Page 7: ...wer indicator light After power is on the indicator light will display in red 6 DC 12 V power connector AC power supply connecting port 7 RS232 output RS232 output port at most 7 cameras can be connected in a serial connection 8 RS232 input RS232 input port at most 7 cameras can be connected in a serial connection 9 HDMI output HDMI output 10 Audio input Support Line In Mic In 11 Audio output Supp...

Page 8: ... Function Description 3 2 1 The tally indicator light function may be enabled through the control of VISCA command The setting method is as follows Tally Mode 8x 01 7E 01 0A 01 0p FF p 0 OFF p 4 On half brightness p 5 On full brightness ...

Page 9: ...C601P size Length x Width x Height 186 71 x 67 0 x 67 0 mm Weight 1 Kg 4 1 2 Installation method 4 1 2 1 Wall mounted frame The camera is installed on the wall using Lumens VC WM11 optional wall mounted frame 4 1 2 2 Tripod The camera is mounted on a 1 4 20 UNC PTZ tripod deck ...

Page 10: ... 4 2 2 Connecting to Internet Remark For details of web page connection setting and description please refer to Chapter 5 Network Function Settings Description 4 2 3 Connecting AUDIO IN HDMI 3G SDI cable Monitor or HDTV Router or Hub Network cable MIC or audio mixer Audio Cable ...

Page 11: ...English 10 4 2 4 Connecting RS 232 RS 232 serial connection With RS 232 in out at most 7 Lumens cameras can be connected RS 232 pin definition description ...

Page 12: ... Connecting via switch or router 2 To connect directly through network cable the IP address of the computer should be changed so that it is on the same network segment as the camera e g The factory preset default IP address of VC BC601P is 192 168 100 100 The computer IP address must be set with the same network segment such as 192 168 100 101 so that the computer can be connected correctly with t...

Page 13: ...ing methods Install Lumens VMS software Please download from the Lumens official website http www mylumens com support Open LUMENS VMS software Search for the camera Press automatically search for the device button to locate the VC BC601P camera Click VC BC601P in the list and start operation after connecting to network Note When using automatic search the camera and computer must be in the same n...

Page 14: ...ccount admin Default Password 9999 Default 5 2 4 Using RTSP Player to View the Images In addition to the browser and VMS other free softwares also can be used for RTSP connection such as VLC Quick Time and PotPlayer RTSP connection address formats are as follows RTSP Main Streaming 1080P H 265 rtsp camera IP 8554 hevc RTSP Sub1 Streaming 1080P H 264 rtsp camera IP 8557 h264 RTSP Sub2 Streaming 720...

Page 15: ...English 14 ...

Page 16: ... Language selection Currently the system supports English Traditional Chinese and Simplified Chinese For the first login please refer to 5 3 3 User Management Modify the default password 4 Remember password Save user account name and password to the browser When you log in next time there is no need to re enter them 5 Login Log into the administrator screen on the website 2 5 1 3 4 ...

Page 17: ...SAVE or LOAD 2 Zoom ratio Adjust the zoom in or zoom out ratio via scroll bar 3 Preview window Display the screen currently captured by the camera 4 Switch to Full Screen Switch the preview window to full screen 5 Power button Turn on or turn off the camera power 5 3 3 Account Management 1 2 3 4 VC BC601P VC BC601P 4 5 2 3 1 ...

Page 18: ...List of accounts Edit Modify the user password and permissions Delete Delete the user account 5 3 4 Setting System Setting No Item Function Descriptions 1 Resolution Set the resolution of the camera resolutions supported by the camera are as follows 1080p 59 94 1080p 50 1080p 29 97 1080p 25 720p 59 94 720p 50 720p 29 97 720p 25 After switching the resolution the camera will restart If there are no...

Page 19: ...g 3 VC BC601P supports 3 streaming outputs Please refer to 5 3 5 1 Streaming Parameter Setting for relevant settings 4 Enable Streaming Confirm whether or not the streaming function is opened 5 Force I Frame Check this item to insert IDR frame into specified series flow and apply its setting User s setting will be reserved and displayed in GUI interface 5 3 5 1 Streaming parameter setting Function...

Page 20: ...vel Gain The gain limit is adjustable when the exposure mode is set to Manual Iris The size of aperture is adjustable when the exposure mode is set to Manual or Aperture Priority WDR Set the level of wide dynamic range WDR in order to obtain better images Shutter Speed The shutter speed is adjustable when the exposure mode is set to Manual or Shutter Priority 3 White Balance Mode Select the color ...

Page 21: ...lue Manually adjust blue red color temperature 4 Focus Mode Select manual automatic focus Focus Range The focusing range is adjustable when the focus mode is set to Manual AF Sensitivity Set automatic focus sensitivity AF Frame Set automatic focus range 5 MIRROR Mirror Set the mode at which the image is mirror and flipped Off Mirror Flip Mirror Flip ...

Page 22: ...ad When no custom setting is needed reset the picture parameters back to the factory default by selecting this item 6 Gamma Gamma Level adjustment Adjustable when the image mode is set to Custom 7 Brightness Brightness adjustment Adjustable when the image mode is set to Custom 8 Hue Contrast adjustment Adjustable when the image mode is set to Custom 9 Saturation Saturation adjustment Adjustable wh...

Page 23: ...Item Function Descriptions 1 Audio Enable Turn on off sound 2 Audio In Type Set MIC In Line In 3 Audio Volume Adjust Volume 4 Encode sample rate Set Encode sample rate 48 KHz AAC 44 1 KHz AAC 16 KHz G 711 8 KHz G 711 1 2 3 4 VC BC601P ...

Page 24: ... images on the RTMP service platform To upload to YouTube for live streaming the audio function must be turned on first 3 RTSP Setting Enable Disable Multicast It is suggested to enable Multicast when the number of users online watching the live image simultaneously is more than 4 4 MPEG TS Setting 1 Port must be set in the range above 1024 with a maximum value of 9999 The following port has been ...

Page 25: ...t value is 120 microseconds 6 SNTP Setting Set SNTP Server IP 7 Port Setting Set HTTP and HTTPS ports The default values are Port 80 and Port 81 respectively Remark Change of setting is available only when DHCP function of camera is closed 5 3 10 Setting Time No Item Function Descriptions 1 Camera Time Display the date and time of the camera 2 Set the Time Manual Configuration Set time manually Sy...

Page 26: ...he camera firmware may be upgraded via web page For the upgrade method please download the FW upgrade manual from Lumens official website 5 3 12 Setting Maintenance Error Log No Item Function Descriptions 1 Error Logs If the camera encounters errors an error code log will be established VC BC601P VC BC601P ...

Page 27: ... The web page setting parameters can be exported from the computer and imported applied to another camera 3 Baud Rate Set the camera Baud Rate for the use of connecting RS 232 communication 5 3 14 About No Item Function Descriptions 1 Camera ID Display the camera name 2 Firmware Version Display the firmware version of the camera 3 Serial No Display the camera serial No 1 2 3 VC BC601P 1 2 3 VC BC6...

Page 28: ... Make sure you have plugged in the power cord 2 When using a PoE connection ensure that the power supply supports IEEE 802 3af hubs 2 There is no image output from VC BC601P 1 Check the power supply or PoE supply functions 2 Make sure the display supports the output resolution in general the resolution is 1080p60 720p60 3 Replace the cables and make sure they are not faulty 3 RS 232 cannot be cont...