FCB-ER8550/CR8550(GB) D-201-100-12(1)
Command List (4/7)
Command Set
Command
Command Packet
Comments
CAM_Aperture
Reset
8x 01 04 02 00 FF
Aperture Control
Up
8x 01 04 02 02 FF
Down
8x 01 04 02 03 FF
Level
8x 01 04 42 00 00 0p 0q FF
pq: Aperture Gain (00h to 0Fh)
Mode
8x 01 05 42 01 0p FF
p: Auto (0)/Manual (1) selection
BandWidth
8x 01 05 42 02 0p FF
p: Bandwidth setting
0: default (initial value)
1: low bandwidth
2: mid bandwidth
3: wide bandwidth
4: broad bandwidth
Crispening
8x 01 05 42 03 0p FF
p: Crispening (0h to 7h)
H/V balance
8x 01 05 42 04 0p FF
p: H/V Balance (5h to 9h)
B/W balance
8x 01 05 42 05 0p FF
p: B/W Balance (0h to 4h)
Limit
8x 01 05 42 06 0p FF
p: Limit (0h to 7h)
HighLightDetail
8x 01 05 42 07 0p FF
p: High light detail (0h to 4h)
SuperLow
8x 01 05 42 08 0p FF
p: Super low emphasis (0h to 7h)
CAM_HR
On
8x 01 04 52 02 FF
High Resolusion Mode On/Off
Off
8x 01 04 52 03 FF
CAM_NR
Noise Reduction
8x 01 04 53 pp FF
p: NR setting (00h: Off, 01h to 05h: level, 7Fh: 2D/3D manual
setting)
2D NR/3D NR
8x 01 05 53 0p 0q FF
p: 2D NR level (0h to 5h), q: 3D NR level (0h to 5h)
CAM_Stabilizer
On
8x 01 04 34 02 FF
Image Stabilizer On/Off
Off
8x 01 04 34 03 FF
CAM_Gamma
—
8x 01 04 5B 0p FF
p: Gamma Setting (0: Standard, 1: Straight, 2: Pattern)
Pattern
8x 01 05 5B 0p 0q 0r FF
pqr: Selection pattern (001h to 200h)
Offset
8x 01 04 1E 00 00 00 0s 0t 0u FF
s: Polarity offset (0 is plus, 1 is minus)
tu: Offset s=0 (00h to 40h)
Offset s=1 (00h to 40h)
CAM_HighSensitivity
On
8x 01 04 5E 02 FF
High Sensitivity mode On/Off
Off
8x 01 04 5E 03 FF
CAM_LR_Reverse
On
8x 01 04 61 02 FF
LR Reverse On/Off
Off
8x 01 04 61 03 FF
CAM_Freeze
On
8x 01 04 62 02 FF
Freeze On/Off
Off
8x 01 04 62 03 FF
CAM_PictureEffect
Off
8x 01 04 63 00 FF
Picture Effect Setting
Black & White
8x 01 04 63 04 FF
CAM_PictureFlip
On
8x 01 04 66 02 FF
E-Flip On/Off
Off
8x 01 04 66 03 FF
CAM_ICR
On
8x 01 04 01 02 FF
ICR Mode On/Off
Off
8x 01 04 01 03 FF
CAM_AutoICR
On
8x 01 04 51 02 FF
Auto ICR Mode On/Off
Off
8x 01 04 51 03 FF
Threshold
8x 01 04 21 00 00 0p 0q FF
pq: ICR On
Off Threshold Level (00h to FFh)
CAM
_AutoICRAlarmReply
On
8x 01 04 31 02 FF
Auto ICR switching Alarm On/Off
Off
8x 01 04 31 03 FF
(Reply)
y0 07 04 31 02 FF
ICR Off
On
y0 07 04 31 03 FF
ICR On
Off