140
TAV-L1
Pin No.
Pin Name
I/O
Description
82
EMERGENCY
_DOWN
O
Emergency stop (lower direction) detection sensor input terminal
"H": emergency stop detect
83
EMERGENCY
_UP
O
Emergency stop (upper direction) detection sensor input terminal
"H": emergency stop detect
84
DROP_DOWN
_DETECT
O
Deceleration start position (lower direction) detection sensor input terminal
"H": deceleration start position detect
85
DROP_UP
_DETECT
O
Deceleration start position (upper direction) detection sensor input terminal
"H": deceleration start position detect
86
STOP_DOWN
_DETECT
O
Stop position (lower direction) detection sensor input terminal "H": stop position detect
87
STOP_UP
_DETECT
O
Stop position (upper direction) detection sensor input terminal "H": stop position detect
88
MO_PHASE
O
Lift motor drive direction control signal output terminal
89
MO_SR
O
Synchronous rectification control signal output to the lift motor driver
90
MO_RESET
O
Reset signal output to the lift motor driver "L": reset
91
MO_MODE
O
Mode selection signal output to the lift motor driver "L": cool mode, "H": normal mode
92
NO USE
O
Not used
93
PANEL_FAIL_IN
I
Abnormal voltage detection signal input from the LCD panel unit "L": abnormal voltage detect
94, 95
KEY2, KEY1
I
Key input terminal Not used
96
VSS
-
Ground terminal
97
KEY0
I
Key input terminal Not used
98
VREF
I
Reference voltage (+3.3V) input terminal
99
VCC
-
Power supply terminal (+3.3V)
100
MO_FAULT
I
Fault state detection signal input from the lift motor driver "L": fault stare, "H": normal state