2-3 (E)
DXF-20W
2 mm (H size)
Chart frame
Underscan monitor frame
2-2-3. Horizontal Frame Adjustment
Note
This adjustment and “2-2-2. Focus Adjustment”, “2-2-4.
Heater Voltage Adjustment” and “2-2-5. Bright Calibration
Adjustment” affect with each other. Therefore, repeat the
adjustment until all specifications are met.
Preparation
.
Object:
Resolution chart
.
Measuring equipment: Waveform monitor
.
Remove the eye cap from the viewfinder.
.
Viewfinder
BRIGHT control
→
Mechanical center
CONTRAST control
→
Mechanical center
PEAKING control
→
Fully counterclockwise
3
Adjustment Procedure
1.
Adjust the lens zoom so that the resolution chart
frame coincides with the underscanned picture frame
on the monitor screen.
2.
Set the resolution on the monitor screen to the best
state with the lens focus.
3.
Adjust the lens iris so that the white level at VIDEO
OUT connector on the camera is as follows.
For NTSC: 100
±
2 IRE
For PAL:
700
±
14mV
Monitor screen
4.
Adjust
1
RV2 (H-SIZE WIDE)/VF-88 board so that H
size of resolution chart is underscanned by approxi-
mately 2 mm from the CRT picture frame.
Viewfinder screen
RV4
RV3
RV2
RV1
VF-88 board
Содержание DXF-20W
Страница 1: ...ELECTRONIC VIEWFINDER DXF 20W SERVICE MANUAL 1st Edition ...
Страница 20: ......
Страница 24: ......
Страница 26: ......
Страница 30: ......
Страница 31: ...6 1 DXF 20W 6 1 DF 70 VA 229 DF 70 VA 229 Section 6 Board Layouts VA 229 SUFFIX 11 DF 70 SUFFIX 11 ...
Страница 32: ...6 2 DXF 20W 6 2 VF 88 VF 88 VF 88 SUFFIX 11 VF 88 SUFFIX 11 ...
Страница 33: ......
Страница 34: ...Printed in Japan Sony Corporation 2006 5 08 2006 DXF 20W SY J E 9 968 256 01 ...