5-61
Confidential
DMP-1000P (AEP)
•
DK-39E BOARD IC2101
µ
PD72069GF-3BA (FLOPPY DISK DRIVE CONTROLLER)
Pin No.
Pin Name
I/O
Description
1
NC
—
Not used (open)
2
GND3
—
Ground terminal (buffer system)
3
NC
—
Not used (open)
4
EM2
O
Spindle motor on/off control signal output of the drive unit Not used (open)
5
EM1
O
Spindle motor on/off control signal output of the drive unit Not used (open)
6
GND3
—
Ground terminal (buffer system)
7
EM0
O
Spindle motor on/off control signal output of the drive unit Not used (open)
8
DIR
O
Signal specifying the seek direction is output to the floppy disk drive unit
“L”: centripetal direction, “H”: centrifugal direction
9
GND3
—
Ground terminal (buffer system)
10
STEP
O
Signal generating seek pulses is output to the floppy disk drive unit
11
WDATA
O
Written data output to the floppy disk drive unit
12
GND3
—
Ground terminal (buffer system)
13
WE
O
Signal specifying data writing to drive is output to the floppy disk drive unit
14
ENIDX
I
Signal that makes INDEX signal and RDATA signal active is input from the floppy disk drive
unit Fixed at “L” in this set
15
NC
—
Not used (open)
16
VDD2
—
Power supply terminal (+5V) (analog system)
17
NC
—
Not used (open)
18
CGP1
O
Phase error in sub PLL system is output
19
NC
—
Not used (open)
20
CGP2
O
Phase error in sub PLL system is output
21
GND2
—
Ground terminal (analog system)
22
LPF1
O
Phase error in main PLL system is output
23
LPF2
O
Phase error in main PLL system is output
24
TRK0
I
Signal showing that the head of drive positions at cylinder 0 is input from the floppy disk drive
unit
25
NC
—
Not used (open)
26
WPRT
I
Signal showing that the medium is in write protect status is input from the floppy disk drive unit
27
RDATA
I
Read data input from the floppy disk drive unit
28, 29
NC
—
Not used (open)
30
READY
I
Signal showing that the drive is ready is input from the floppy disk drive unit
31
2SIDE
I
Signal showing that a both sided medium is inserted in the drive is input
Not used (fixed at “L”)
32
FLT
I
Signal showing that the drive is in fault status is input Not used (fixed at “H”)
33
ENPCS
I
Not used (fixed at “L”)
34
ACTL
I
Initial setting signal to select active level of drive interface signal is input
Fixed at “H” in this set (Set the active level is “L”)
35
MSEL
I
Not used (fixed at “L”)
36
SIDE
O
Signal selecting the head of both sided drive is output to the floppy disk drive unit
37
GND3
—
Ground terminal (buffer system)
38
FLTR
O
Signal to reset the drive fault status is output Not used (open)
39
HDLD
O
Signal setting the head of drive in load status is output Not used (open)
40
GND3
—
Ground terminal (buffer system)
41
LCT
O
Signal showing that the head of drive positions at the inside from No. 43 cylinder is output
Not used (open)
42, 43
VDD1
—
Power supply terminal (+5V) (digital system)