Installation

1-1. Installation Environment

Operating temperature:

+

d

C to 

+

40 

d

C

Storage temperature:

_

20 

d

C to 

+

60 

d

C

Operating humidity:

20 % to 90 % (non-condensing)

Do not install the DEP-100 in the following locations.

.

Areas where the unit will be exposed to direct sun light
or any other strong lights.

.

Areas near heat sources.

.

Dusty areas or areas where it is subject to vibration.

.

Areas with strong electric or magnetic fields.

.

Areas where is subjected to electricity noise.

.

Areas where is subjected to static electricity noise.

1-2. Power Supply

1-2-1. Power Specifications

Power requirements: AC 100 to 240 V

50/60 Hz

Current consumption: maximum 1.0 A (at 100 V)

maximum 0.5 A (at 240 V)

A switching regulator is used for the power supply of the
DEP-100.  The voltage within the range of 100 V to 240 V
can be used without changing the supply voltage.

n

As the inrush current at turn-on is maximum 20 A (at 100
V)/maximum 40 A (at 240 V), the capacity of the AC
power must be adequate with the inrush current of maxi-
mum 20 A (at 100 V)/maximum 40 A (at 240 V).
If the capacity of the AC power is not the adequately large,
the breaker of the AC power at the supply side will operate
or the DEP-100 will abnormal operate.

1-2-2. Power Cord

w

To avoid a fire or an electric shock, be sure to use the
designated power cord.  And do not damage to the power
cord.

n

For the customer outside of the area as shown above or in a
part of Europe, the above-mentioned power cords can not
be used.
Use the power cord that is applicable to the places in the
world.

1-557-377-01

1

AC inlet

2

Power cord for the customer in the U.S.A. and Canada.
  

1

 Power cord set

  

2

 Plug holder (Black)           2-990-242-01

2

1

Power cord for the customer in Europe except the 
United Kingdom.
  

1

 DK-2401(AE) (approx. 2.4 m)

  

2

 Plug holder (Black)           2-990-242-01

  Plug holder is included in DK-2401(AE).

2

1

Power cord for the customer in the United Kingdom.

1

 DK-2401(UK) (approx. 2.4 m)

  

2

 Plug holder (Black)           2-990-242-01

  Plug holder is included in DK-2401(UK).

AC inlet

AC inlet

Содержание DEP-100

Страница 1: ...DEP 100 DIGITAL EFFECTS PROCESSOR INSTALLATION MANUAL 1st Edition Serial No 10001 and Higher ...

Страница 2: ...lessure n effectuer que les réparations indiquées dans le mode d emploi à moins d être qualifié pour en effectuer d autres Pour toute réparation faire appel à une personne compétente uniquement For the U S A Attention when the product is installed in Rack 1 Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack ple...

Страница 3: ...tion Space 1 2 E 1 4 Matching Connectors and Cables 1 3 E 1 5 Input and Output Signal of Connector 1 4 E 1 6 Switch Setting on Connector Panel 1 7 E 1 7 Switch Setting on Board 1 7 E 1 8 Rack Mounting 1 8 E 2 Service Overview 2 1 Cleaning of Air Filter 2 1 E 2 2 Periodic Replacement 2 1 E 2 3 Information of LEDs on Board 2 2 E 2 4 ISR 2 3 E 2 4 1 Functions Overview 2 3 E 2 4 2 Usage of ISR Functio...

Страница 4: ...for peripheral equipment connections etc Section 2 Service Overview Explains the cleaning and summary of ISR Related manual Besides this installation manual the following manuals are available for the DEP 100 Operation Manual Supplied with the DEP 100 This manual explains the overview of the DEP 100 and the system configuration examples Maintenance Manual Not supplied with the DEP 100 This manual ...

Страница 5: ...imum 20 A at 100 V maximum 40 A at 240 V the capacity of the AC power must be adequate with the inrush current of maxi mum 20 A at 100 V maximum 40 A at 240 V If the capacity of the AC power is not the adequately large the breaker of the AC power at the supply side will operate or the DEP 100 will abnormal operate 1 2 2 Power Cord w To avoid a fire or an electric shock be sure to use the designate...

Страница 6: ...tion of air in the place where the DEP 100 is installed The rear side of the DEP 100 should be at least 20 cm away from walls for ventilation and maintenance 1 3 External Dimensions and Installation Space 866 2 424 450 304 8 83 7 66 57 2 132 4 3U 14 5 44 254 101 6 482 465 424 Front view Right side view Top view Front panel Unit mm Mass 13 5 kg ...

Страница 7: ...UT DIGITAL I O BNC 75 Z male 1 560 069 11 PROGRAM OUT 5C 2V cable 1 DSK INPUT SDI INPUT MOUSE 9 pin serial mouse 2 ISR D sub 25 pin male 1 566 356 11 Solderless type 1 564 747 11 Solder type GPI BNC 75 Z male 1 560 069 11 EFFECT KEY ON KEY OFF REMOTE OUT D sub 9 pin male 1 560 651 00 Connector REMOTE IN 1 561 749 00 Shell RCC 5G 10G 30G cable 3 1 5C 2V Max 100 meters Fujikura America Inc Fujikura ...

Страница 8: ... 270 Mbps Conform to SMPTE 259M ITU R BT 656 SUB BNC x 1 Component digital 270 Mbps Conform to SMPTE 259M ITU R BT 656 6 GPI EFFECT KEY ON KEY OFF BNC x 3 GPI input for effect control TTL Level 10 k Z Output Connector 2 MONITOR OUT BNC x 1 Analog composite video 1 0 V p p 75 Z sync negative 3 PROGRAM OUT BNC x 4 Component digital 270 Mbps Conform to SMPTE 259M ITU R BT 656 1 5 Input and Output Sig...

Страница 9: ...terface Mouse control 8 ISR D sub 25 pin connector RS 232C interface For ISR Interactive Status Reporting 9 REMOTE OUT D sub 9 pin connector RS 422A interface Remote control REMOTE IN D sub 9 pin connector RS 422A interface Remote control 1 5 Input and Output Signal of Connector ...

Страница 10: ...XD Received Data Input 4 RTS Request to Send Output 5 CTS Clear to Send Input 6 DSR Data Set Ready Input 7 SG Signal Ground 8 DCD Data Carrier Detect Input 9 to 19 NC 20 DTR Data Terminal Ready Input 21 to 25 NC 9 9 9 9 9 REMOTE OUT RS 422A D sub 9 pin Female Pin No Signal 1 GND 2 RM RX _ 3 RM TX 4 GND 5 SPARE 6 GND 7 RM RX 8 RM TX _ 9 GND REMOTE IN RS 422A D sub 9 pin Female Pin No Signal 1 GND 2...

Страница 11: ...tch on the SEC 54 and VSW 61 boards IF 643 board n The addresses on the board are shown by marks S600 A 9 RESET switch Resets the CPU on the IF 643 board S700 A 9 MODE SELECT switch Factory setting All switch levers are set to OFF 1 6 Switch Setting on Connector Panel 1 7 Switch Setting on Board ON OFF 75 Z REF VIDEO 75 Z termination switch ON 1 2 3 4 5 6 7 8 indicates the switch lever position 1 ...

Страница 12: ...ke sure that all the units in the rack should be operat ed within the temperature range of 5 dC to 40 dC Connect the enough long cables on the rear panel considering that the DEP 100 is pulled out An installation manual is supplied with the RMM 30 rack mount rail However follow the instructions in this manual Because the rack mounting procedures of the DEP 100 differ somewhat from the procedures e...

Страница 13: ... 100 using the six screws B4 x 8 supplied with the DEP 100 5 Loosen the screws fastening the rear bracket to the outer rail and adjust the position of the rear bracket with the rack depth 6 Attach the front and rear brackets to the outside of the rack temporarily using the eight screws B5 x 8 supplied with RMM 30 Rack Rack Unit mm 12 7 12 7 31 75 12 7 31 75 B5 x 8 Outer rail B5 x 8 1 8 Rack Mounti...

Страница 14: ...s B5 x 8 secured tempo rarily in the step 6 n When securing the front brackets to the rack by screws pull out the DEP 100 about 20 cm 8 inches and fasten the screws of the front brackets to the rack 9 After installing the DEP 100 in the rack secure the unit to the rack by the prepared four screws RK5 x 16 and four washers n When the DEP 100 is mounted in a rack the maximum traveling distance is il...

Страница 15: ... 2 Service Overview 5 Clean the dust on the filter using a vacuum cleaner n If the filter is too much dusty it is recommended to wash it When washing the filter be sure to dry it well 6 After cleaning fasten the filter to the tapes 2 2 Periodic Replacement To maintain the performance of the DEP 100 it is recom mended to replace the fan motor periodically Fan motor A fan motor is installed on the r...

Страница 16: ...EM indicator Lights off 525 60 system Lights up 625 50 system D500 to D503 green A 7 8 Factory use D504 to D507 red A 8 Factory use D703 to D706 red A 10 Unassigned D707 red A 10 SYSTEM CONTROL ERROR indicator Lights up when CPU does not run normally D708 green A 11 SYSTEM CONTROL STATUS indicator Blinks when CPU runs normally 2 3 Information of LEDs on Board 1 2 3 4 5 6 7 8 9 10 11 12 A B C IF 64...

Страница 17: ...tion program software For the program software usage installation and opera tion of a personal computer in which this program software can be used please consult with your local Sony s sales service office The preparation below is required when managing the DEP 100 by ISR 1 Connect a personal computer to the ISR connector D sub 25 pin of the DEP 100 using a RS 232C cross cable 2 Check the DIP swit...

Страница 18: ...nd descriptions are as follows Test No Description 1 Initial Self Diagnostics 2 VSW 45 board sense 3 SEC 39 board sense 4 Flash memory It can be requested these self diagnostics menus by using HELP TST command When the self diagnostics is complete the DEP 100 returns ATN OPC 2 4 3 Supported Commands The DEP 100 supports the following commands For more detailed information of each command refer to ...

Страница 19: ...re module which downloaded is stored in flash memory The DEP 100 operates with this software module from next boot up When downloading is complete the DEP 100 returns ATN OPC TST Test Query This command requests the results of the self diagnostic stored in the buffer The responses for each self diagnostics are as follows 1 Initial Self Diagnostics No error Error occurred 2 VSW 45 board sense Exist...

Страница 20: ......

Страница 21: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Страница 22: ...Printed in Japan Sony Corporation 1997 10 08 Broadcast Products Company 1997 Published by Broadcast Products Company DEP 100 SY J E 3 193 433 01 ...

Отзывы: