2-19
DCR-IP210/IP210E/IP220/IP220E
[SERVICE POSITION TO CHECK THE CAMERA SECTION]
Connection to Check the Camera Section
To check the CAMERA section, set the CAMERA to the “Forced camera power ON” mode.
To obtain the focus manually, connect both of the FP-538 board and the FP-539 board.
Setting the “Forced Camera Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 01, and
press the PAUSE button of the adjustment remote
commander.
Exiting the “Forced Camera Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
LANC jack
DC-098 board
DI-087 board
ST-076 board
CN4201
CD-406 board
CN1000
DI-087 board
CN2019
VC-308 board
FP-538 board
FP-539 board
Adjustment remote
commander (RM-95)
AC power
adaptor
AC IN
Mechanism deck
Lens block assembly
FP-542 flexible board
Must be connected.
Cabinet (F) block assembly
Cabinet (rear) block assembly
This wire must be connected
to obtain the focus manually.
CN457
CN001
CN453
CN455
CN456
CN458
CN463
CN452
(CPC)
CN461
CN2020
CN451
DC-IN connector
Control switch block
(SS-2980)
WWW.FREESERVICEMANUALS.INFO
12/2
WWW.NOSTATECH.NL
Worlf of free manuals