5-18
3-2.
Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Mode
CAMERA
Subject
Subject more than 500 m away
(Subjects with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Adjustment Page
F
Adjustment Address
14 to 25, 87 to 8B
Adjusting method:
Order Page Address Data
Procedure
1
Set the zoom lens to the
TELE end and expose a
subject that is more than 500
m away (subject with clear
contrast such as building,
etc.). (Nearby subjects less
than 500 m away should not
be in the screen.)
2
0
01
01
3
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
4
6
01
13
Press PAUSE button.
5
Place the ND filter on the
lens so that the optimum
image is obtain.
6
6
01
29
Press PAUSE button. (Note 1)
7
6
02
Check the data changes to “01”.
8
F
87
Check the data changes to “00”.
Note 1:
The adjustment data will be automatically input to
page: F, address: 14 to 25 and 87 to 8B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 3.
(Refer to page 5-14)
3
0
01
00
4
Perform “Flange Back Check”.
4.
Flange Back Check
Mode
CAMERA
Subject
Siemens star chart
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Specified value
Focused at the TELE end and
WIDE end
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 1.0 m
from the front of the lens.
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
2
0
01
01
3
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
4
Shoot the Siemens star chart
with the zoom TELE end. At
this time, the center of
Siemens star chart should be
in the center of the LCD
screen.
5
Check that the lens is
focused.
6
6
2C
01
7
While observe the LCD
screen, change the zoom to
the WIDE end and check that
the lens is focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
Release the data setting
performed at step 3.
(Refer to page 5-14)
3
0
01
00