TORQUE MEASUREMENT
Mode
Torque Meter
Meter Reading
2.0 – 8.0 mN
⋅
m
FWD
CQ-102AS
(20 – 80 g
⋅
cm)
(0.28 – 1.12 oz
⋅
inch)
FWD
0.15 – 0.6 mN
⋅
m
Back Tension
CQ-102C
(1.5 – 6.0 g
⋅
cm)
(0.021 – 0.083 oz
⋅
inch)
5.0 – 17.7 mN
⋅
m
FF
CQ-201AS
(50 – 177 g
⋅
cm)
(0.7 – 2.48 oz
⋅
inch)
5.0 – 17.7 mN
⋅
m
REW
CQ-201B
(50 – 177 g
⋅
cm)
(0.7 – 2.48 oz
⋅
inch)
TAPE TENSION MEASUREMENT
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 80 g
(more than 2.82 oz)
Содержание CMT-DF1