11
Name and Function of Parts
h
Microphone power supply switch
Sets whether to supply power to a microphone connected to
the AUDIO IN connector.
+48V:
Co48 V power supply to the microphone.
OFF:
Does not supply power to the microphone.
(No function has been assigned to the lowermost
position. No power is supplied to the microphone when
the switch is in this position.)
Note
To 12 V power, contact a Sony sales representative
or Sony service representative.
i
REMOTE connector (8-pin)
Connects to an RCP-1000/1500-series Remote Control Panel
or MSU-1000/1500 Master Setup Unit.
It is used with an RS-422A connected device under menu
control. Set the TRUNK menu on the CCU to IF: 232C/422A,
IF: 1CH for use.
Note
When the camera is connected to a camera control unit, do not
connect a remote control device or master setup unit to this
connector.
j
AUX (auxiliary connection) connector (12-pin)
Connects to a lens cable. A lens cable connection enables the
unit to control lens functions.
With SKC-PB40 attached
a
DC OUT (DC power supply output) light
On:
Indicates output from the 3-system DC OUT connector is
normal, when power is supplied from a CCU.
Flashing:
Indicates that the protection circuit for one or two of
the three systems has been activated.
Off:
Indicates that the protection circuit for all three systems
have been activated.
b
DC OUT 1/2 (DC power supply output 1/2) connectors
(XLR 4-pin)
Supplies power to optional external devices (14 V output
voltage, 6.5 A maximum current).
c
DC OUT 24V (24 V DC power supply output) connector
(4-pin)
Supplies power to optional external devices (24 V output
voltage, 3.7 A maximum current).
Note
The total maximum output power for all three systems is
135 W. The maximum output power is limited by the length of
the optical camera cable, temperature, and other factors.
1
2
3
AUX
DC IN
AUDIO IN
INTERCOM
REMOTE
LINE
MIC
AES/EBU
+48V
OFF
TRACKER
DC OUT
RET CTRL
PUSH
PUSH
DC OUT
24V
PUSH
PUSH