3-14 (E)
CA-550
CA-550P
3-4-9. R-Y/B-Y DC Balance Adjustment
Equipment
:
Oscilloscope (LIMITER
→
OFF)
Test Point
:
TP5 (GND:E1)/MD-103 (C-1)
Adjustment Points :
1
RV8 (R-Y DC BAL)/MD-103 (D-4)
1
RV12 (B-Y DC BAL)/MD-103 (D-4)
Adjustment Procedure :
Adjust
1
RV8 and
1
RV12 alternately so that the V BLKG
portions are flat.
3-4-10. R-Y/B-Y 90
°
Adjustment
Notes:
• This adjustment is necessary only when replacing FL5
on the MD-103 board.
• Use a plastic core driver to adjust
1
FL.
Equipment
:
Digital voltmeter or Oscilloscope
(DC mode)
Preparation :
• CCU-700/700P/700A/700AP setting
Extend the DM-94 board of the CCU.
Test Point
:
TP14 (GND:E12)/DM-94 (K-5)
Adjustment Point :
1
FL5/MD-103 (D-2)
Adjustment Procedure :
Adjust
1
FL5 so that a negative absolute value of DC
voltage is maximum.
The voltage changes slowly. When reading the value,
allow for 2 or 3 seconds after turning
1
FL5.
V rate
MD-103 BOARD (COMPONENT SIDE)
3-4. MD-103 Board Adjustment
MD
PROMPT
GENLOCK
A
1
2
3
4
B
C
D
E
F
G
RV12
TP5
RV8
FL5
E1
Содержание CA-550
Страница 1: ...CAMERA ADAPTOR CA 550 550P MAINTENANCE MANUAL 1st Edition Serial No 50001 and Higher ...
Страница 6: ......
Страница 12: ...1 6 E CA 550 CA 550P 1 2 4 Wiring Diagrams for Cables CCA 5 Cable CCZ Cable 1 2 Connectors and Cables ...
Страница 28: ......
Страница 46: ......
Страница 74: ...4 28 CA 550 CA 550P ...
Страница 88: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...
Страница 102: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...
Страница 104: ...8 2 b CA 550 CA 550P 8 2 b ...
Страница 106: ...8 4 b CA 550 CA 550P 8 4 b ...
Страница 108: ...8 6 b CA 550 CA 550P 8 6 b ...
Страница 110: ...8 8 b CA 550 CA 550P 8 8 b ...
Страница 112: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...