3-10 (E)
CA-550
CA-550P
3-4. MD-103 Board Adjustment
This adjustment requires a completely-aligned MSU-700.
Refer to Section 3-1-3 and 3-1-4 for connection and initial
settings.
3-4-1. VCO 45 MHz Adjustment
Note :
• This adjustment requires longer warm-up periods (10 to
30 minutes).
Equipment
:
Frequency counter
Test Point
:
TP9 (GND:E1)/MD-103 (F-2)
Adjustment Point :
1
RV13 (VCO ADJ)/MD-103 (F-3)
Specifications
:
45, 000, 000
±
10 Hz
3-4-2. Y Level Adjustment
Equipment
:
Oscilloscope
Preparation :
• Setting of MSU-700 operation panel
TEST 2 button
→
ON (Lights)
Test Point
:
TP61 (GND:TP59)/extension board
(extending MD-103)
Adjustment Point :
1
RV1 (VTR Y LVL)/
MD-103 (A-3)
Specifications
:
A = 1400 mV
±
2%
Note :
• After the adjustment is complete, be sure to turn off the
TEST 2 button of MSU-700.
H rate
MD-103 BOARD (COMPONENT SIDE)
3-4. MD-103 Board Adjustment
MD
PROMPT
GENLOCK
A
1
2
3
4
B
C
D
E
F
G
RV1
RV13
TP9
E1
Содержание CA-550
Страница 1: ...CAMERA ADAPTOR CA 550 550P MAINTENANCE MANUAL 1st Edition Serial No 50001 and Higher ...
Страница 6: ......
Страница 12: ...1 6 E CA 550 CA 550P 1 2 4 Wiring Diagrams for Cables CCA 5 Cable CCZ Cable 1 2 Connectors and Cables ...
Страница 28: ......
Страница 46: ......
Страница 74: ...4 28 CA 550 CA 550P ...
Страница 88: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...
Страница 102: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...
Страница 104: ...8 2 b CA 550 CA 550P 8 2 b ...
Страница 106: ...8 4 b CA 550 CA 550P 8 4 b ...
Страница 108: ...8 6 b CA 550 CA 550P 8 6 b ...
Страница 110: ...8 8 b CA 550 CA 550P 8 8 b ...
Страница 112: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...