3-3 (E)
CA-550
CA-550P
3-1-4. Initial Settings
CA-550/550P
n
When switching the following switches from a customer-
set position, it is recommended to record the setting state
of the customer in the table below.
After adjustment is complete, be sure to return the switches
to their customer-set position.
Board
Switch
Initial setting
Customer-set position
MD-103
S3
GENLOCK
AU-211
SW1
C (CARBON)
SW2-1
OFF
SW2-2
OFF
SW2-3
OFF
SW2-4
OFF
SW2-5
ON
SW2-6
OFF
SW2-7
OFF
SW2-8
OFF
SW3-1
OFF
SW3-2
ON
SW4
OFF
SW5
PHANTOM
SW6
MIC1
DM-98
S1-1
OFF
S1-2
OFF
S1-3
OFF
S1-4
ON
MSU-700 Operation Panel
• CAM POWER/Signal output select buttons
ALL button
→
OFF (Stays out)
CAM PW button
→
ON (Stays lit)
TEST 1 button
→
OFF (Stays out)
TEST 2 button
→
OFF (Stays out)
BARS button
→
OFF (Stays out)
CLOSE button
→
ON (Stays lit)
• CAM/CCU Function ON/OFF buttons
KNEE OFF button
→
OFF (Stays lit)
DETAIL OFF button
→
OFF (Stays lit)
MATRIX OFF button
→
OFF (Stays lit)
AUTO KNEE button
→
OFF (Stays out)
• Others
GAMMA OFF button
→
ON (Stays out)
MASTER GAIN button
→
0 (0 dB)
3-2. AU-211 Board Adjustment
1
RV1 and
1
RV3 on the AU-211 board adjust the VTR
playback audio level and side tone level respectively, and
they can be set according to a customer’s preference.
To output the VTR playback audio or the side tone signal,
switch settings of the AU-211 board are required.
For details, refer to Section 1-4 “Function of Internal
Switches—AU-211 Board”.
3-2-1. BATTERY ALARM SET Adjustment
Note :
• Adjustment for
1
RV4 is very critical. Do not turn it as
far as the circuit normally activates.
Equipment
:
Digital voltmeter
Oscilloscope
DC variable power supply
Preparation :
• Supply about +13 Vdc from the DC variable power
supply via the DC IN connector.
Adjustment Point :
1
RV4/AU-211 (D-4)
Adjustment Procedures:
1.
Turn
1
RV4 fully clockwise.
2.
Measure voltage at TP84 (GND:GND A)/extension
board (extending AU-211).
3.
Adjust the voltage at TP84 for +11.20
±
0.05 V.
4.
Slowly turn
1
RV4 counterclockwise observing the
waveform at TP42/extension board (extending AU-
211) on the oscilloscope.
5.
Adjust
1
RV4 so that an 1.0-Hz, 8.0-Vp-p rectangler
wave just appears.
A
1
2
3
4
B
C
D
E
F
G
AU
MIC PW
ON
OFF
MIC
D
C
RV3
RV1
RV4
AU-211 BOARD (COMPONENT SIDE)
3-1. Preparation
3-2. AU-211 Board Adjustment
Содержание CA-550
Страница 1: ...CAMERA ADAPTOR CA 550 550P MAINTENANCE MANUAL 1st Edition Serial No 50001 and Higher ...
Страница 6: ......
Страница 12: ...1 6 E CA 550 CA 550P 1 2 4 Wiring Diagrams for Cables CCA 5 Cable CCZ Cable 1 2 Connectors and Cables ...
Страница 28: ......
Страница 46: ......
Страница 74: ...4 28 CA 550 CA 550P ...
Страница 88: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...
Страница 102: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...
Страница 104: ...8 2 b CA 550 CA 550P 8 2 b ...
Страница 106: ...8 4 b CA 550 CA 550P 8 4 b ...
Страница 108: ...8 6 b CA 550 CA 550P 8 6 b ...
Страница 110: ...8 8 b CA 550 CA 550P 8 8 b ...
Страница 112: ...5 4 OHB 400 500 500WS PAL OHB 450 451 550 550WS PAL 5 4 ...