4-14
BVP-500
BVP-500P
Note:
The values used in the above adjustments are under the
conditions that the white clip level is set to 109 IRE (for
NTSC) or 763 mV (for PAL).
When the white clip level is set to other value than 109
IRE or 763 mV, use the following table to set the levels of
the knee point and knee slope.
White Clip Level (Unit: IRE/mV)
109/763
107/749
105/735
103/721
Knee point
98/686
98/686
96/672
96/672
Knee slope
109/763
109/763
107/750
107/750
White clip
109/763
107/749
105/735
103/721
4-10. Crispening Adjustment
Note:
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Equipment
: Waveform monitor
Test Point
: MONITOR connector
Object
: Grayscale chart
Preparations:
• Connect the waveform monitor to the MONITOR
connector.
• DETAIL OFF button/MSU operation panel
→
ON (goes out)
• S650 (MONITOR SELECT)/IF-538 panel
→
VBS
• Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
Iris of the lens
: A = 90
±
2 IRE (for NTSC)
A = 630
±
14 mV (for PAL)
(Waveform Monitor)
Adjustment Procedures:
1.
Adjust the auto white balance.
WHITE button/MSU operation panel
→
ON (Lights)
2.
Adjust the crispening. Proceed as follows.
MSU menu operation:
• PAINT button
→
ON (Lights)
• Touch panel operation
(Page 1/3)
→
Detail
→
Detail1
Adjustment item
: Crispening
Specifications
: Set the numeral value to -99
once, and turn slowly for
increment until the noise at the
black level of the waveform is
just decreased, or an appropriate
crispening level is obtained.
4-9. Knee and White Clip Adjustment
4-10. Crispening Adjustment