3-11
BVP-500
BVP-500P
Page
Ver.
Item
Settings
Contents
BLACK
CLEAR
Throw MENU SELECT
Resets numeric settings to “0” on the BLACK SHADING page.
SHADING
switch to ENTER
(When you throw MENU SELECT switch to ENTER, the “CLEAR” indication
to execute.
flashes. Throw MENU SELECT switch to ENTER again to execute; throw to
CANCEL to cancel.)
AUTO SET UP
AUTO BLACK
Throw MENU SELECT
Starts to automatically adjust the black balance.
switch to ENTER
to execute.
AUTO BLACK
Throw MENU SELECT
Starts to automatically adjust the black balance.
switch to ENTER
(To abort a processing during execution, throw MENU SELECT switch
to execute.
to ENTER.)
LEVEL AUTO
Throw MENU SELECT
Starts to automatically adjust the level in the internal circuits.
c)
switch to ENTER
(To abort a processing during execution, throw MENU SELECT switch
to execute.
to ENTER.)
1.10
AUTO HUE
Throw MENU SELECT
Sets the skin detail hue function automatically.
switch to ENTER
(Locate the desired skin color within the gate marker of VF and measure.)
to execute.
WHITE
Throw MENU SELECT
Starts to automatically adjust the white shading.
SHADING
switch to ENTER
(To abort a processing during execution, throw MENU SELECT switch
to execute.
to ENTER.)
BLACK
Throw MENU SELECT
Starts to automatically adjust the black shading.
k)
SHADING
switch to ENTER
(To abort a processing during execution, throw MENU SELECT switch
to execute.
to ENTER.)
1.10
COLOR REF
Throw MENU SELECT
Makes a color reference to compensate the difference in colors
(SELF)
switch to ENTER
between OHBs using a single camera. (Locate the desired colors of a
to execute.
Macbeth chart within the gate marker of VF and measure. To abort a
processing during execution, throw MENU SELECT switch to ENTER.)
m)
1.10
COLOR SETUP Throw MENU SELECT
Automatically calculates the color matrix from the reference.
(SELF)
switch to ENTER
(Locate the desired colors of a Macbeth chart within the gate marker of
to execute.
VF and measure. To abort a processing during execution, throw MENU
SELECT switch to ENTER.)
n)
DATE/TIME
DD/MM/YY
Adjusts a built-in timer. (HH;hour/MM;minute only)
HH:MM:SS
DATE ON BARS ON,
[OFF]
Selects whether the date characters are mixed with a camera output
signal in the color-bar mode, or not.
(This setting is valid only when the DISPLAY switch is set to on or off.)
TIME ON BARS ON,
[OFF]
Selects whether the time characters are mixed with a camera output
signal in the color-bar mode, or not.
(This setting is valid only when the DISPLAY switch is set to on or off.)
c)
When executing the LEVEL AUTO, data set through the menu is all cleared and the automatic level adjustment is performed in
sequence, After the adjustment is complete, adjustment result is stored as a master setup data.
1. A reference file which is reference for adjustment is loaded .
2. Lens is autmatically closed and the black balance is automatically adjusted.
3. The white balance is automatically adjust using TEST 2 (3-step) signal.
m
This white balance adjustment compensates a drift of the gain of an amplifier, does not compensate color temperature for an actual object.
The gamma and knee compensation values do not change with a lapse of time because of the digital-processing camera.
Therefore, the gamma and knee compensation values remains the values stored in the reference file.
k)
Before first using the camera with the OHB-400/500/500WS (or their PAL version) installed, or After replacing the CCD unit, be sure
to execute the automatic black shading adjustment.
m) When performing compensation between two or more cameras, use the MSU.
n)
Differing from the color-setup operation by plural cameras, a data transfer is not performed.
Execute to recalculate. After execution, the color matrix data is temporarily reflected in the OHB matrix of the System Config menu.
Execute the OHB FILE STORE of the Triming menu to store the color matrix data.
3-1. Setup Menu
3-1-3. Maintenance Menu
Содержание BVP-500
Страница 14: ...1 6 BVP 500 BVP 500P 1 3 Outside Dimentions 1 3 Outside Dimentions Unit mm ...
Страница 15: ...1 7 BVP 500 BVP 500P 1 3 Outside Dimentions With BVF 77 77CE attached Unit mm http getMANUAL com ...
Страница 22: ...1 14 BVP 500 BVP 500P ...
Страница 120: ......