Sony BVE-700A Скачать руководство пользователя страница 12

1-8 (E)

BVE-700A

LEDs

Ref. No. Adress

Name

Function

Normal state

D900 to

(H-6)

_

7SEG LED

00

D915

Error status indication.
Normal: Displays 00.
When an error occurs: Displays an error code.
(See Maintenance Manual for details.)

D930

(H-4)

SW_ACT

Status indication of SWER on the rear panel.

Lights up

Lights up in green when the SWER communication
system can be operated correctly at startup.

D931

(H-4)

MIX_ACT

Status indication of MIXER on the rear panel.

Lights up

Lights up in green when the MIXER communication
system can be operated correctly at startup.

D932

(H-4)

P1_ACT

Status indication of PLAYER-1 on the rear panel.

Lights up

Lights up in green when the PLAYER-1 communica-
tion system can be operated correctly at startup.

D933

(H-4)

P2_ACT

Status indication of PLAYER-2 on the rear panel.

Lights up

Lights up in green when the PLAYER-2 communica-
tion system can be operated correctly at startup.

D934

(H-4)

P3_ACT

Status indication of PLAYER-3 on the rear panel.

Lights up

Lights up in green when the PLAYER-3 communica-
tion system can be operated correctly at startup.

D935

(H-3)

REC_ACT

Status indication of RECORDER on the rear panel.

Lights up

Lights up in green when the RECORDER communica-
tion system can be operated correctly at startup.

D936

(H-3)

PNL_ACT

Status indication of PANEL on the rear panel.

Lights up

Lights up in green when the PANEL communication
system can be operated correctly at startup.

D937

(H-3)

EDL_ACT

Status indication of EDL on the rear panel.

Lights off

Lights up in green when sending data.

D940

(H-4)

3.3 V

3.3 V power supply status indication.

Lights up

Lights up in green when 3.3 V power is supplied.
Lights off at error.

D941

(H-4)

5 V

5 V power supply status indication.

Lights up

Lights up in green when 5 V power is supplied.
Lights off at error.

D942

(H-4)

12 V

12 V power supply status indication.

Lights up

Lights up in green when 12 V power is supplied.
Lights off at error.

D1000

(H-4)

REF_EXT

Lights up in green when a signal is input to REF

Lights up

VIDEO IN on the rear panel and is correctly
recognized.

D1001

(H-4)

PLL_LOCK

Lights up in green when the reference signal is

Lights up

locked.

D1500

(H-3)

ETHER_100

Lights up in green when the mode of NETWORK

Lights off

is set to 100 Mbps base.

D1502

(H-3)

ETHER_ACT Lights up in green when communication is

Lights off

established through NETWORK on the rear

(when network is not

panel.

connected)

D1700

(H-5)

TEMP

Blinks in green when the temperature in

Lights off

the BVE-700A turns 85 

°

C or higher.

At the same time, TEMP ERROR is displayed
on the scratchpad on the control panel.

D1702

(H-4)

FAN

Lights up in green when the temperature in

Lights off

FAST

the BVE-700A turns 45 

°

C or higher.

Содержание BVE-700A

Страница 1: ...EDITING CONTROL UNIT BVE 700A INSTALLATION MANUAL 1st Edition Revised 1 Serial No 10001 and Higher ...

Страница 2: ... compétente uniquement Attention when the product is installed in Rack 1 Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack please make sure that the rack does not overload the supply circuit 2 Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack p...

Страница 3: ...Supply 1 1 E 1 3 Installation Space 1 2 E 1 4 Matching Connectors and Cables 1 4 E 1 5 Input Output Signals of Connectors 1 5 E 1 6 Function of Switch and LED on Board 1 7 E 1 7 Rack Mounting 1 9 E 1 8 Installing the BKE 701A 1 10 E 2 Service Overview 2 1 Removing Reinstalling Front Panel 2 1 E 2 2 Cleaning 2 1 E 2 2 1 Filter 2 1 E 2 2 2 Fan 2 1 E 2 3 Data Backup Capacitor 2 2 E ...

Страница 4: ...s the information that premise the service of BVE 700A BKE 701A based on components replaced Semiconductor Pin Assignments CD ROM Available on request This Semiconductor Pin Assignments CD ROM allows you to search for semiconductors used in B P Company equipment The maintenance manual contains a complete list of semiconductors and their ID Nos and thus should be used together with the CD ROM Part ...

Страница 5: ...er requirements AC 100 to 240 V 10 50 60 Hz Current consumption Maximum AC100 V 1 A Maximum AC240 V 0 5 A with all optional boards installed n As the inrush current at turn on is the maximum 35 A at 100 V 85 A at 240 V the capacity of the AC power must be commensurate in it If the capacity of the AC power is not the adequately large the breaker of the AC power at the supply side will operate or th...

Страница 6: ...1 2 E BVE 700A 1 3 Installation Space Processor unit 520 440 465 57 2 375 482 61 380 17 5 132 4 Unit mm ...

Страница 7: ...1 3 E BVE 700A Control panel unit Unit mm 340 315 5 281 277 2 315 16 9 15 ...

Страница 8: ...ll 9 pin 1 561 749 00 Processor unit GPI D sub 15 pin Female D sub 15 pin Male Connector 15 pin Male 1 564 600 11 1 Junction Shell 15 pin 1 563 376 11 Processor unit SDI IN BNC 75 Z BNC 75 Z SDI OUT 5C FB coaxial cable Processor unit REF VIDEO BNC 75 Z BNC 75 Z Belden 8281 coaxial cable Processor unit Control panel unit PANEL D sub 15 pin Female D sub 15 pin Male Connector 15 pin Male 1 564 600 11...

Страница 9: ... No Signal Function 1 _ No Connection 2 RXD Received data 3 TXD Transmitted data 4 _ No Connection 5 GND Ground 6 _ No Connection 7 RTS Not used at present 8 CTS Not used at present 9 _ No Connection _ EXT VIEW _ 1 5 6 9 _ EXT VIEW _ 5 1 9 6 GPI D sub 15 pin Female Pin No Signal Function 1 GND Ground 2 OUT 1A Relay output 1A 3 OUT 2A Relay output 2A 4 OUT 3 TTL Open collector output 3 5 OUT 4 TTL ...

Страница 10: ...Pin No Signal Function 1 TX Transmitted data 2 TX_ Transmitted data _ 3 RX Received data 4 _ No Connection 5 _ No Connection 6 RX_ Received data _ 7 _ No Connection 8 _ No Connection Control panel unit EDITOR D sub 15 pin Female Pin No Signal Function 1 GND Ground 2 RX_ Received data _ 3 TX Transmitted data 4 GND Ground 5 _ No Connection 6 12 V Panel Power Supply 7 12 V Panel Power Supply 8 12 V P...

Страница 11: ...01 H 6 Mode select Sets the operation mode switch 2 S901 1 to S901 5 Sets the Video Format Video Format S901 1 2 3 4 5 1125 59 94 OFF OFF OFF OFF OFF 1125 29 97 PsF OFF OFF OFF OFF ON 525 59 94 OFF OFF OFF ON OFF 1125 50 OFF ON ON OFF OFF 1125 25 PsF OFF ON ON OFF ON 625 50 OFF ON ON ON OFF 1125 24 PsF ON OFF ON OFF ON 1125 23 98 PsF ON OFF OFF OFF ON OFF OPEN ON CLOSE Push the switch to the DOWN ...

Страница 12: ...t startup D936 H 3 PNL_ACT Status indication of PANEL on the rear panel Lights up Lights up in green when the PANEL communication system can be operated correctly at startup D937 H 3 EDL_ACT Status indication of EDL on the rear panel Lights off Lights up in green when sending data D940 H 4 3 3 V 3 3 V power supply status indication Lights up Lights up in green when 3 3 V power is supplied Lights o...

Страница 13: ...hten the screws on the rack angle and fix the unit in the rack If the screws on the rack angle are not tightened the unit may slip from the rack and fall causing injury c When mounting the unit in the rack note the following Be sure to mount in the rack with two persons or more Be careful not to catch your fingers or hands in the rack mount rail or others Mount in the rack in a stable position n I...

Страница 14: ...ool at the side of the equipment with the rail and slide the equipment to the rear n The rack tools are hooked on the rails as shown below 6 Turn off the main power of this unit and disconnect the plug from the outlet 7 Fully loosen the four screws with drop safe and remove the front panel 8 Fix the rack angle in the rack using the specified screws 9 Attach the front panel to the equipment 1 8 Ins...

Страница 15: ...ter The filter on the rear of the front panel can easily accumu late the dust Be sure to remove dust by cleaning as follows 1 Remove the front panel Refer to Section 2 1 2 Remove the dust accumulated on the filter with a vacuum cleaner n Cleaning the filter by washing in water is recommend ed when there is a heavy accumulation of dust Be sure to dry the filter completely after it has been washed 2...

Страница 16: ...ave the main power of the BVE 700A turned on for about four hours or longer in order to charge this capacitor The data is retained for four to five days when the capaci tor is fully charged under normal operating temperature and humidity However this period may vary depending on the storage environment Be sure to save necessary data in an external media ...

Страница 17: ... de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich ...

Страница 18: ...Printed in Japan Sony Corporation 2007 9 16 2005 BVE 700A SY J E 3 991 224 02 ...

Отзывы: