1-16 (E)
S801-6 through S801-8(H-1) :
Physical channel setting switch
Sets the physical channel
(*3)
.
Physical channel
S801-6
S801-7
S801-8
CH1
OFF
OFF
OFF
CH2
OFF
OFF
ON
CH3
OFF
ON
OFF
CH4
OFF
ON
ON
CH5
ON
OFF
OFF
CH6
ON
OFF
ON
CH7
ON
ON
OFF
CH8
ON
ON
ON
S801-6 through S801-8 are set to OFF at the factory.
(*3) : The physical channel is the number assigned to each
processor so that the control panel can discriminate
multiple processors.
COR407(A-6) through COR412(B-6) : Factory use
These switches are used for the adjustment in the factory.
n
Be sure to use these switches for factory setting (USE).
[LED]
D2 (Green)(E-1) : RUN indicator
Lights during the CPU operation.
D3 (Green)(E-1) : VD indicator
Indicates the existence of VD signal.
Lights when VD signal is normally input to the board.
D802(F-1) through D810(G-1) : Factory use
These LEDs are used for the adjustment in the factory.
D819(E-1) through D822(F-1) : Factory use
These LEDs are used for the adjustment in the factory.
MPU-70 board
[Switch]
S3(J-4) : Emulator mode setting switch
n
Be sure to use this switch for setting at the factory.
Factory setting:
S3-1
S3-2
S3-3
S3-4
S3-5
S3-6
S3-7
S3-8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
S201(F-1) : Reset switch
Resets the CPU on the MPU-70 board.
[LED]
D202 (Green)(G-1) : FD indicator
Blinks whenever CPU interrupt processing is executed in
each field.
D203 (Green)(G-1) : RUN indicator
Lights during the CPU operation.
D202
D203
S201
A side (Component side)
S3
K
J
H
F
E
D
C
B
A
4
3
2
1
G
1-8. Switch Settings on Boards and LEDs Description