26
Instruction for use | Supercal 5
designation
Description of the
value
2 outputs
B1
at terminal 16/17
B2
at terminal 18/19
Normal mode
Voltage
max. 30 VDC
Current
max. 100 mA
Voltage drop
approx. 1,3 V at 20 mA
Duty cycle
1 : 1
Electrical pulse duration
100 ms conductive
Maximum electrical pulse frequency
5 Hz (+/- 20%)
Fast mode
Voltage
max. 30 VDC
Stream
max. 100 mA
Voltage drop
approx. 1,3 V at 20 mA
Pulse type
linear or scaled pulses
Maximum electrical pulse frequency
200 Hz (+/- 20%)
5.6.1.1 Technical Characteristics of the Two Open-Collector
Pulse Outputs
Output
SC5
Vout
Iout
Additional counter
0V
Counter 2
Counter 1
16
18
17
Circuit diagram
Control of the outputs
1 / f
t1
t2
U+
0V
Inactive
Active
t1
tm
Pulse control
Designation
Description
Normal mode
t1 = t2 min. 100 ms (at duty cycle = 50%)
Fast mode (D battery or mains operation)
t1 = t2 min. 2,5 ms (at duty cycle = 50%)
Vout max.
< 30 V inactive, 0,3 V active
Vout min.
2,0 V inactive, 0 V active
Iout max.
< 5 µA inactive at 30 V, < 100 µA active
Iout min.
0 µA inactive, 1,65 µA active at 3,6 V