45
Decommissioning
ATTENTION
Damage of the battery cells by
deep discharge!
If the storage system is not
connected to the utility grid, the
battery modules can be damaged by
excessive and prolonged discharge.
▶
Do not leave the storage system
disconnected for longer than six
months (see "Storing the system"
for more information.)
Shutting the storage system down
ATTENTION
Damage of system parts by forced
disconnect!
If there is no emergency:
▶
Shut the storage system
down.
If there is no emergency, do
not turn off the storage system
by forcibly removing power, by
turning off the DC circuit breaker,
or by using the battery emergency
switch, as these methods may result
in undesirable behavior.
Shut down the storage system
1. Press "Shutdown" button
▶
Press the grid of six dots in the upper right
corner of the screen.
▶
Press the "Settings" icon.
▶
Press "Shutdown" button.
2. Confirm shut-down
▶
Press "Yes" to confirm shut-down.
The shut down takes approximately 60 seconds.
3. Turn off battery modules
▶
Starting with battery module 0, depress the
"Power" button for 3 seconds on each battery
module, they may take several seconds the
power down.
▶
Ensure both the "Power" and "Status" LEDs are
off on each battery module.
Emergency switch-off
In case of an emergency, the storage system
can be switched off by the main circuit breaker F1
or the external emergency switch (if installed).
Fig. 94 F1 circuit breaker
▶
In case of an emergency, switch off the main
circuit breaker F1 in the interior of the main
cabinet or the external emergency switch (if
installed).
▶
Only switch off the main circuit breaker F1 if it
can be reached without danger.
▶
If possible, shut off battery modules by
depressing the "Power" button for 3 seconds,
the batteries may take several seconds the
power down.
Recycling and certificates
The sonnen energy storage system battery
modules comply with RoHS and contains none of
the following substances: lead, cadmium, mercury,
hexavalent chromium, polybrominated biphenyl
(PBB) and polybrominated diphenyl ether (PBDE).
Do not dispose of the sonnen energy storage
system or its battery modules in anywhere other
than certified electronics and battery facility! You
S1