44
state of charge drops below 7% then the system
will go into standby and will not provide power to
the home. The system will automatically wake up
during the three time periods for 6 minutes in an
attempt to find some way to charge the batteries-
either using solar or a generator. If no source
is detected then the system will go back into
standby until the next time period.
Although the times can be customized,
a suggested setting for the microgrid times are
0800, 1000 and 1200. If the system can’t find a
charging source by noon, then there is probably
a bigger issue with the system charging, e.g.
low PV production, generator is out of fuel,
dead generator battery, etc. The timers will
be disregarded by the system if the Re-enable
Microgrid setting is switched to NO.
System
Fig. 93 System information
This screen shows various information about
the storage system that could be useful in
troubleshooting.