Warranty and Safety Information
ii
Sonifex HY-02 User Handbook
Unpacking the HY-02
Each HY-02 is shipped in protective packaging and should be inspected for damage before use. Where an item is found to
have transit damage, notify your supplier immediately with all the relevant details of the shipment. Packing materials
should be kept for inspection and also for if the product needs to be returned.
Returning the Warranty Card
In order to register the date of purchase so that we can keep you informed of any design improvements or modifications,
it is important to complete the warranty registration document that is enclosed and return it to Sonifex Ltd in the UK.
For your own records you should write down the serial number (which can be found on the rear of the HY-02).
Serial Number
………………………………..
Safety of Mains Operated Equipment
This equipment has been designed to meet the safety regulations currently advised in the country of purchase and it
conforms to the safety regulations specified by use of the CE Mark.
Warning :
There are no user serviceably parts inside the machine. If you should ever need to look inside the unit,
always disconnect the mains supply before removing the equipment covers.
Warning:
This apparatus is intended for use when powered by the HY-02-B power supply unit. Other usage will
invalidate any approval given to this apparatus if, as a result, it ceases to comply with the edition of BS6301 to which it
was approved.
Warning:
The equipment B.T. plug should only be connected with apparatus complying with BS6301 and the connection
to the network must not be hard wired. Interconnection directly or indirectly with equipment ports marked in accordance
with BS6301 to unmarked ports may produce hazardous conditions on the network and advice should be obtained from a
competent engineer before such a connection is made.
Warning:
This apparatus
must
be earthed by means of the earth connector on the rear panel, and the B.T. plug should
be disconnected from the telecommunications network
before
disconnecting the earth. Disconnection of this earth
connection may render the equipment unsafe, with a consequential possible electrical shock hazard from exposed metallic
parts.
Warning:
The barriered ports ‘NTTP’ and ‘Handset’ must not be connected directly or indirectly to the unbarriered ports,
‘Line Input’, ‘Line Output’, ‘Mic Input’ or ‘Remotes’.
Voltage Setting Checks
The rear panel of the equipment carries the Serial Number of the machine. The operating voltage of the HY-02 is hard-
wired to be either 115V or 230V. Ensure that the machine operating voltage is correct for your mains power supply. The
safety specification of your HY-02 complies with local requirements and must be earthed through the mains connector.
The available voltage settings are : -
Country code A 115 V operation
Country code E 230 V operation
Fuse Rating
The HY-02
is supplied with a single fuse in the live conducting path of the power infeed at the power supply. For reasons
of safety it is important that the correct rating and type of fuse is used. Incorrectly rated fuses could present a possible
fire hazard, under equipment fault conditions. The fuse ratings for HY-02
are :-
Country code A 115 V operation - 200mA
5 x 20mm SB
Country code E 230 V operation - 100mA
5 x 20mm SB
The active fuse is fitted at the power supply on the outside of the unit.
Power Cable and Connection
An IEC power connector is supplied with the HY-02 which has a moulded plug attached – this is a legal requirement. If no
moulded plug has been supplied with your HY-02, please contact your supplier, because an IEC connector is always
supplied from the Sonifex factory.