Introduction
2
Sonifex HY-02 User Handbook
units are required, they can be slotted into a rack and connected to a single power supply unit, saving money on
duplicating power supplies and casing.
The HY-02 consists of two parts:
1. A telephone hybrid section. This can be either a telephone hybrid or a ringing detector.
2. The power supply section. This supplies
±
15V d.c. to the electronic hybrid section and is connected to the telephone
hybrid processor by means of short link cables. It has an overvoltage protected output and is separately enclosed. It
is supplied as a single unit for use with one telephone hybrid unit or as a dual unit for the twin hybrids (HY-02D and
HY-02T). Earth bonding from the mains IEC input connector is carried through the connection cable and multiway
socket to the electronic hybrid unit.
HY-02
Automatic TBU, free standing with PSU
HY-02D
Twin automatic TBU, free standing with PSU
HY-02S
Single automatic TBU, rackmounted with PSU
HY-02T
Twin automatic TBU, rack mounted with PSU