background image

Sonifex Pty Ltd T/A Innes Corporation 
12/6 Leighton Pl 
Hornsby, NSW 2077, Australia 
Phone: +61 2 9987 0499 
Fax: +61 2 9476 4950 
E-mail: 

[email protected]

 

Website: http://www.innescorp.com.au 

3

Digitorc 4 Manual

 

Electromagnetic Compatibility 
 

 

 

 
 
 
 
 
 

 
This  product  complies  with  the  relevant  tested  clauses  of  AS/NZS  CISPR  22:2009  +A1:2010  and 
AS/NZS CISPR 13:2012. 
 
This  product  complies  with  the  relevant  tested  clauses  of  EN55022:2010,  EN55013:2013, 
EN55024:2010, EN61000-3-2:2009 and EN61000-3-3:2013. 
 
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful  interference  when  the  equipment  is  operated  in  a  commercial  environment.  This  equipment 
generates,  uses,  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in  accordance 
with the instruction manual, may cause harmful interference to radio communications. Operation of this 
equipment  in  a  residential  area  is  likely  to  cause  harmful  interference  in  which  case  the  user  will  be 
required to correct the interference at his own expense. 

WARNING 

 

This is a Class A product. In a domestic environment this product may cause radio 
interference in which case the user may be required to take adequate measures. 

 

Содержание Digitorc 4

Страница 1: ...561 871 Sonifex Pty Ltd T A Innes Corporation 12 6 Leighton Pl Hornsby NSW 2077 Australia Phone 61 2 9987 0499 Fax 61 2 9476 4950 E mail sales innescorp com au Website http www innescorp com au Digito...

Страница 2: ...evel adjustment audio mixing buffering and a single lane PCIe 1 1 interface Output physical sampling rates of 96kHz 88 2kHz 48kHz 44 1kHz and 32kHz are available with the Windows sampling rate convert...

Страница 3: ...for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercia...

Страница 4: ...d from that application A Windows XP compatibility mode is available to provide full mixer access to the hardware if needed Peak meters for WDM drivers are only available through the mixer API under W...

Страница 5: ...ia Audio Controller Right click on it select Update Driver Software then click on Browse my computer for driver software and click on the Browse button to navigate to the driver s location Click on Ne...

Страница 6: ...ht click on Digitorc 4 and select Properties Now click on the Configuration tab and select the desired output rate and or synchronisation After clicking on OK it may take up to a minute for Windows to...

Страница 7: ...bled as follows Right click on the loudspeaker symbol in the bottom right hand corner of the screen and select Recording Devices Right click on any of the sources and check Show Disabled Devices which...

Страница 8: ...t the bottom right hand corner of the screen select Recording Devices right click anywhere in the window and select Show Disabled Devices Now right click on the desired Wave Out Mix device and select...

Страница 9: ...aviour under Windows XP where each input output pair had its own mixer device How this will work with any particular application that uses the mixer API can only be determined by experimentation Audio...

Страница 10: ...e was a need to support extended bit depth To achieve this Microsoft introduced a new data format descriptor called WAVE_FORMAT_EXTENSIBLE This provides additional information including the number of...

Страница 11: ...hone 61 2 9987 0499 Fax 61 2 9476 4950 E mail sales innescorp com au Website http www innescorp com au 11 Digitorc 4 Manual Digitorc 4 Pinout 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 1...

Отзывы: