background image

8

3

Dante Controller

8

3

Dante Controller

Configuring a Device

In order to open the ‘Device View’ window for a device in Dante Controller,
double click the name of that device in the rou�ng grid.

Device Name

To change the device name, open the ‘Device View’ window and click on
the ‘Device Config’ tab.

Fig 3-4: Device Config Tab

In the ‘Rename Device’ field the user can change the name that appears in
Dante Controller for the device. Change the name in the field and click
apply. The name is then updated in the rou�ng grid.

Channel Labels

The labels of transmit and receive channels can also be changed. By default,
the channels are labelled with numbers.

Fig 3-5: Device with Default Labels

Open the ‘Device View’ window, and navigate to the ‘Receive’ or ‘Transmit’
tab. Within the ‘Receive' tab enter the new channel label in the ‘Channel’
field.

Fig 3-6: Changing Receive Label

Содержание AVN-AESIO8

Страница 1: ...8 Output Dante Interface PoE AVN AIO8 8 Input 8 Output Dante Interface Dual PoE AVN AO8R HANDBOOK 16 Input Dante Interface PoE AVN AI16 16 Input Dante Interface Dual PoE AVN AI16R 16 Output Dante Int...

Страница 2: ...out the express wri en permission of Sonifex Ltd Unless otherwise noted all names of companies products and persons contained herein are part of a completely fic ous adapta on and are designed solely...

Страница 3: ...ntroller Applica on Window 7 Fig 3 4 Device Config Tab 8 Fig 3 5 Device with Default Labels 8 Fig 3 6 Changing Receive Label 8 Fig 3 7 Changing Transmit Label 9 Fig 3 8 Channels with Updated Labels 9...

Страница 4: ...ine you can increase your product warranty to 2 years and we can also keep you informed of any product design improvements or modifications To register your product please go online to www sonifex co...

Страница 5: ...ate of despatch the Contract means the quota on these Condi ons of Sale and any other document incorporated in a contract between the Company and the Purchaser This is the en re Contract between the p...

Страница 6: ...er economic losses The Company accordingly excludes all liability for the same e At the request and expense of the Purchaser the Company will test the Goods to ascertain performance levels and provide...

Страница 7: ...duct Email technical support sonifex co uk for the repair upgrade returns procedure or for support ques ons regarding the product opera on Item Quality Product unit 1 Handbook 1 Conformity The product...

Страница 8: ...y become waste All products manufactured by Sonifex Ltd have the WEEE direc ve label placed on the case Sonifex Ltd will be happy to give you informa on about local organisa ons that can reprocess the...

Страница 9: ...eutrik XLR connectors Dante network connec on for configura on using Dante Controller AES67 opera on Dante Domain Manager compliant 1U 19 rack mount form factor Powered by PoE Adjustable global 0dBFS...

Страница 10: ...the front panel are the status LEDs and reset bu on Clock The clock status LED is illuminated green when the device is a PTP master or synced to a valid PTP master PoE The PoE status LED is illuminat...

Страница 11: ...p level is selectable between 12dBu 18dBu and 24dBu It is a global se ng that affects all inputs and outputs Reset In the unlikely event that the unit fails to respond press the reset bu on to reboot...

Страница 12: ...AIO4 Rear Panel AVN AIO8 R 8 Input 8 Output Dante Interface Single Dual PoE On the AVN AIO8 and AVN AIO8R eight locking XLR line inputs and eight XLR line outputs are available Fig 2 6 AVN AIO8 Rear P...

Страница 13: ...available Fig 2 10 AVN AO16 Rear Panel Fig 2 11 AVN AO16R Rear Panel AVN AESIO8 R AES 8 Input 8 Output Dante Interface Single Dual PoE On the AVN AESIO8 and AVN AESIO8R eight locking XLR AES inputs an...

Страница 14: ...Each output is individually buffered so that a short circuit on one output will not affect the others The line outputs have the following pin out Pin Func on 1 Chassis Ground Screen 2 Output Phase Pos...

Страница 15: ...ante Controller 3 3 Dante Controller Dante Controller is used to create connec ons between Dante enabled devices on the network This sec on will help you get up and running However for more detailed d...

Страница 16: ...Rename Device field the user can change the name that appears in Dante Controller for the device Change the name in the field and click apply The name is then updated in the rou ng grid Channel Label...

Страница 17: ...are a large number of devices on a network it could take a while to look through all the transmi ers and receivers to find the right one Therefore filters are available which allow the user to sort th...

Страница 18: ...eceivers Typing Commentator into the Filter Receivers field all channels with Commentator in their name are displayed Routing Audio Rou ng audio between two Dante devices is simple Click on the box at...

Страница 19: ...r their device is a PTP master or a PTP slave A master device provides a clock which all slave devices on a network remain in sync with The master device is selected using the best PTP clock algorithm...

Страница 20: ...by default Select Enabled from the dropdown menu to enable this mode This op on will be not be available if the device is part of a Dante domain A warning will be displayed asking you to confirm the...

Страница 21: ...P stream has the same prefix as the device you would like to route it to By default the prefix is 69 so the mul cast address of the AoIP stream should be 239 69 X X where the value of X can be any num...

Страница 22: ...indow In the example the channels 01 and 02 are added to the AES67 mul cast flow the Create bu on is then clicked The Transmit tab of the device configura on window will show the new mul cast flow in...

Страница 23: ...ar in Dante Controller with red text Fig 3 25 Red Device Name Indicates Different Network Subnet Opening the Device View for the device will provide details about the problem Fig 3 26 Problem Details...

Страница 24: ...he 192 168 1 X subnet and the computer is on the 10 X X X subnet To correct this edit the computer s IP address In Windows 10 type View Network Connec ons into the search bar Right click the network t...

Страница 25: ...12dBu 18dBu 24dBu Frequency Response 20Hz to 20kHz 0 0 2dB THD N 110dBFS 30dBFS 20Hz to 20kHz 20kHz BW Noise 110dBFS 20kHz BW Rs 200 Crosstalk 100 dB Common Mode Rejec on 60dB 1kHz Audio Output Perfor...

Страница 26: ...8R Ne 1 0kg Gross 1 5kg Ne 2 2lbs Gross 3 3lbs Equipment Type AVN AIO4 4 Input 4 Output Dante Interface PoE AVN AIO8 8 Input 8 Output Dante Interface PoE AVN AIO8R 8 Input 8 Output Dual Dante Interfac...

Страница 27: ...19 Technical Specification 3 Notes...