MRU-30
– USER MANUAL
42
8.2 Charging the rechargeable battery pack
CAUTION!
The MRU-30 meter is powered from a SONEL NiMH 9.6 V battery pack. It can only
be replaced by Sonel or an authorized Sonel service center.
The internal battery charger is powered by an external 12 V Sonel AC power supply adapter. The
device may be also powered from a 12 V car accessory socket.
Charging commences once the power supply adapter is connected to the meter regardless of
whether the meter is on or off.
When the meter is switched off, charging is indicated on the screen by an animated battery
symbol being charged, and indicated by the front panel function LED's cycling in red.
Charging modes:
When the meter is switched off the battery pack is charged in
‘quick charging’ mode. The charging
process takes approx. 4 hours for full charge which is indicated by full battery symbol, the
FULL
mes-
sage and beep. To fully turn the device off unplug the power adapter.
When the meter is switched on, the battery pack is charged in
‘background charging’ mode. Full
charge is indicated by the
FULL
message and beep. If the charging time exceeds 10 hours the meter
will automatically switch off for safety.
To fully turn the device off unplug the power charger and turn the meter off.
CAUTION!
Do not power the meter from sources other than those described in this manual.
Note:
Battery charging may finish prematurely due to interferences in the AC mains supply. If this occurs, turn
the meter off and re-start charging again.
Additional information displayed by the meter
Message
Cause
Proceeding
Err ACU H
°C
Battery is too high.
Wait for the batteries to cool down.
Start the charging procedure again.
Err ACU L
°C
Battery temperature is
too low.
Wait for the batteries to warm up. Start
the charging procedure again.
Err ACU X
(where X is an error
digit indicator)
Charging failure.
Re-start the charging procedure again.
If charging from a 12 V car accessory
socket verify 12 volts is present. If this
error message returns contact Sonel
service as the batteries may need re-
placing.
No battery symbol
(with connected battery charger)
Disconnected or failed
batteries.
Contact
Sonel’s service department.