background image

CONFIGURATION

Once all the connections have been made and 

the  device  is  connected  to  the  mains,  the  device 
shows the screen operating in normal mode with the 
factory settings (page 12).

Press              both keys together for 5 seconds 

to show the main menu on the screen. Here you can 
use the keys               to choose a sub-menu.

Press 

OK

 to enter the chosen sub-menu, such as 

Functions.

Press the keys               to move around the sub-

menu until you find the function you want to configure. 
These screens indicate the status of the function.

Press 

OK

 in the desired function to configure the 

values  (the  value  to  be  changed  flashes).  When
               you have changed the value, press 

OK

 to 

save  and  move  on  to  the  next  value.  When  all  the 
values for this function have been changed, save the 
changes and return to the sub-menu.

Press 

ESC

 to return to the functions sub-menu 

without saving the changes.

Press 

ESC

 again to return to the main menu.

Press 

ESC

 again to return to normal regulation 

operation and after 15 minutes without touching any 
keys the screen light will switch off. Press any key to 
return to normal mode.

This  method  is  applicable  to  all  configuration 

menus and sub-menus.

11

ESC

OK

576

Sonder

ESC

OK

576

Sonder

ESC

OK

576

Sonder

ESC

OK

576

Sonder

ESC

OK

576

Sonder

OPERATION

S S

S S

S S

S S

For normal use of your installation the factory settings are considered to be the most common for each type of system. If they 

are of use to you, the device is ready to control and regulate your installation. If, due to the needs of your installation, you require 
other settings, read this section carefully.

To access the menu from normal operation mode, press any key (except 

ESC

), use the arrows to move to 

PARÁMETROS

, and 

then press 

OK

.

In the menu you can adjust the settings that will define the operation of the installation.

Ÿ

Winter or summer mode

Ÿ

Activation differential

Ÿ

Deactivation differential

Ÿ

Temperature alarm in tanks 1 to 6

Ÿ

Temperature differential (general for all settings)

Ÿ

Minimum setting limit

Ÿ

Maximum setting limit

Ÿ

Minimum ambient limit

Ÿ

Maximum ambient limit

Ÿ

Separate calibration for each probe (T1 to T7)

Ÿ

Priority of tanks 1 to 6

Ÿ

Cooling of accumulators 1 to 6

Ÿ

Sequential priority

Ÿ

Display light

Ÿ

Password (programming protection)

Summer / Winter mode

This parameter allows you to choose between two different settings for tank 
priorities and alarms without having to change them one by one.

- In the 

PARÁMETROS

 menu press               until the 

MODE

 screen appears.

- Press 

OK

 to enter the function settings, and use                           to define the 

desired value.

- Press 

ESC

 to go back and press 

OK

 to save the adjusted values.

Range:  SUMMER or WINTER   /   Default: WINTER

ESC

OK

576

Sonder

Activation differential

This  parameter  defines  the  temperature  difference  required  between  the 
accumulator and the solar collector for the pump to activate.

- In the 

PARÁMETROS

 menu press                           until the 

DIF ACTIVACIÓN

 

screen appears.

- Press 

OK

 to enter the function settings, and use                           to define the 

desired value.

- Press 

ESC

 to go back and press 

OK

 to save the adjusted values.

Range:  4.0 ºC to 20.0 ºC   /   Default: 6.0 ºC

S S

ESC

OK

576

Sonder

Deactivation differential

This  parameter  defines  the  temperature  difference  required  between  the 
accumulator and the solar collector for the pump to deactivate.

- In the 

PARÁMETRO

S menu press               until the 

DIF DESACTIVACIÓN 

screen appears.

- Press 

OK 

to enter the function settings, and use                           to define the 

desired value.

- Press 

ESC

 to go back and press 

OK

 to save the adjusted values.

Range:  1.0 ºC to 4.0 ºC  /   Default: 2.0 ºC

ESC

OK

576

Sonder

26

SETTINGS

S S

S S

S S

S S

S S

MENU

Содержание Allegro 576 BOX

Страница 1: ... Manual Energy control Avenida la Llana Nº 93 P I La Llana 08191 RUBÍ Barcelona Spain Tel 34 93 588 42 11 Fax 34 93 588 49 94 www sonder es info sonder regulacion com SONDER REGULACIÓN S A Allegro 576 RAIL code 20 043 Allegro 576 BOX code 20 054 ...

Страница 2: ...5815VØ MAY 09 2 35 NOTES ...

Страница 3: ...scription Technical specifications Dimensions Connections Operation Getting started Probe and relay test Screen view Configuration Factory settings and resetting Resource control Menu Statistics Functions Systems Settings 33 4 5 6 6 6 6 7 8 8 9 10 11 12 13 16 16 18 22 26 ...

Страница 4: ...modify the product technical data and assembly and use instructions without prior notification WARRANTY CONDITIONS This device has Three year warranty The warranty is limited to the replacement of faulty parts which will be restored to the same condition in which they were received No packaging batteries instructions or any other accessories included with the product will be replaced We cannot acc...

Страница 5: ...3 channels 3 alarms Telephone control landline mobile 1 channel 1 alarm Water meter with pulse output L 50mm L 100mm L 200mm Conductive paste for sheaths 5 PRESENTATION Stainless steel sheaths GSM Consult us about models for remote management and data storage with SD card Visit our WEBSITE New products All our products Technical documentation Catalogues www sonder es Consult our wide range of prod...

Страница 6: ... has reached 45 the swimming pool is heated to dissipate the excess heat instead of accumulating it in the collectors thus preventing the installation from overheating Example with system 6 2 Accumulator priority ºC AC 1 AC 2 AC 3 65 40 5 H W U H Swimming pool In summer Tank alarm ºC AL 1 AL 2 AL 3 70 45 35 Since the underfloor heating does not need to be activated during the summer its priority c...

Страница 7: ...each type of system If they are of use to you the device is ready to control and regulate your installation If due to the needs of your installation you require other settings read this section carefully In the menu you can adjust the parameters that define how the installation will operate default values and setting ranges SETTING RANGE ADJUSTED Adjustment mode Activation differential Deactivatio...

Страница 8: ...lthough only 1 symbol is shown on the screen All the settings are preset to factory default values If these values do not suit the needs of your installation consult page 26 to configure them 8 OPERATION ESC OK 576 Sonder Accumulator cooling This parameter allows you to reduce the temperature of the accumulator by recirculating the collector when it detects that the collector temperature is lower ...

Страница 9: ...key the system returns to normal operation and the relays return to the status required by the system at that time With the password OFF The system does not exit the test menu until the ESC key is pressed forced manual mode Then move on to the relays forced manual where you can manually activate deactivate each relay Press OK to activate deactivate relay R1 Press to move on to the next relay Press...

Страница 10: ...LIGHT TIMER LIGHT parameter OFF 10 ESC OK 576 Sonder This screen informs you that The probe assigned to the radiator has a reading error S S OPERATION SETTINGS 27 Tank temperature alarm This parameter defines a temperature alarm for each accumulator depending on the system a unit heater or cooling system is activated another accumulator is charged or circulation is stopped In the PARÁMETROS menu p...

Страница 11: ...to move to PARÁMETROS and then press OK In the menu you can adjust the settings that will define the operation of the installation Winter or summer mode Activation differential Deactivation differential Temperature alarm in tanks 1 to 6 Temperature differential general for all settings Minimum setting limit Maximum setting limit Minimum ambient limit Maximum ambient limit Separate calibration for ...

Страница 12: ...limit Maximum setting limit Active system 1 1 1 tank 1 pump If the password is activated it is impossible to reset the values and restore the factory settings To do so it is necessary first to deactivate the password value 0 in the settings menu If an unauthorised user tries to reset the values he would press the ESC key for 10 seconds and only be able to enter the probe and relay test When you ex...

Страница 13: ...3 3 1 3 2 3 3 5 1 5 2 5 3 6 1 6 2 6 3 4 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 13 OPERATION Hot water S4 S5 R3 S3 R5 R2 S1 S7 R6 A B C D EXCHANGER PURIFIER F R1 R4 S6 E S1 S2 S3 S4 S5 S6 S7 R1 ...

Страница 14: ... S S S S S OK S S S S S S S S S S S S S S S S ESC S S S S S S S S S S OPERATION collector array 2 pumps 2 tanks collector array tank swimming pool 2 pumps collector array tank heating 2 pumps collector array 2 tanks pump 3 way valve collector array tank swimming pool pump 3 way valve collector array tank heating return pump 3 way valve 2 collector arrays east and west 2 tanks 2 pumps 3 way valve 2...

Страница 15: ...n Use the keys to move on to the next system To confirm the chosen system press OK and press the ESC key to return the previous menu Once the system has been configured the unit saves the changes and returns to normal operation SYSTEMS The representation of the units on these diagrams is symbolic One solar panel means there is one array of solar collectors but when there are 2 it means that there ...

Страница 16: ...e solar system you need for your installation and then the functions since you may not be able to configure the rest of the functions according to relays the systems leaves frees MENU Thermostat 1 2 3 independent Thermostat 1 2 ambient Anti frost Double pump alternation Cooling by unit heater Calorimeter Tubular sensor Return increase OR AND Regulates the temperature of a probe heating underfloor ...

Страница 17: ...s ESC to return to the FUNCIONES menu This function conditions the status of a relay based on the status of all the selected relays For example if you choose R1 as the slave relay and R2 R4 and R6 as the main relays R1 will be activated when R2 AND R4 AND R6 are activated When any one of the main relays is off the slave relay switches off AND ESC OK 576 FUNCTIONS 20 Press OK to enter the function ...

Страница 18: ...to enter the function settings where you can activate deactivate the function and set the total time that each pump will operate before changing 4 to 120 hours Press to change the flashing value and press OK to confirm the selection Press ESC to return to the FUNCIONES menu S S This function allows you to double a pump in your installation so that the two pumps work in alternation Double pump alte...

Отзывы: