WSM6 Manual
Document Ref: UM-8270-000
Issue: A Rev 0
Section 8
94
4.
If less than 23.4V, or zero, a fault on the connector, DAS card or interconnections is
indicated.
5. See
Section 3.5.1
configurations for variant transponders.
8.5
Functional Check
8.5.1
Transponder Mode
1. Check
the
ON
/
OFF
switch on the transponder is in the
OFF
position.
2.
Disconnect the battery pack from the Tx card by disconnecting PL1.
Figure 8-4 – Functional Test Configuration
1
Frequency
6
ANT Coupling
11
Power Supply Unit
2
X10 Probes
7
ANT
12
Switched End cap
3 Ch1
8 Out
13 Battery
Connector
4 Oscilloscope 9 TDR
5 Ext
10 In
October 2011